6.2
MOBA-NMS operation
For the configuration of DTS devices via GUI, MOBA-
NMS (see chapter „3.6 MOBA-
NMS - Network Management System
“) can be used. All configuration possibilities are
subordinated in different configuration pages (called „tabs“). These tabs are connected
to the terminal menu and designated accordingly. Example: The terminal menu
„Configuration
Alarms“ can be found in MOBA-NMS under the tab „Alarms“.
Configuration example of a DTS 4128 timeserver:
For further details on the general MOBA-NMS operation, check the integrated online help
(menu „Help
Show help“).
Important:
In order for the communication between MOBA-NMS and the DTS
devices to work, SNMP must be activated! Set terminal menu
„Configuration
SNMP
SNMP Mode“ to „on“. SNMP is active by
default.
configuration pages
(tabs)