Troubleshooting Chart
Chapter Eight: Troubleshooting
87
- Network status LED
Green
Link OK, On-line, Connected
The device in on-line and has
connection in the established state.
- For a Group 2 only device it means
that this device is not allocated to a
master.
Flashing Green
On-line, Not Connected
Device is on-line but has no
connection in the established state.
- The device has passed The
Dup_MAC_ID test, is on-line, but has
no established connections to other
nodes.
- For a Group 2 only device it means
that this device is not allocated to a
master.
Red
Critical Link Failure
Failed communication device. The
device has detected an error that has
rendered it incapable of
communicating on the network
(Duplicate MAC ID, or Bus-off)
Flashing Red
Connection Time-Out
One or more I/O Connections are in
the Timed-Out state.
Flashing Red & Green Communication Faulted and
Received an Identify Comm
Fault Request - Long Protocol
A specific Communication Faulted
device. The device has detected a
Network Access error and is in the
Communication Faulted state. The
device has subsequently received
and accepted an Identify
Communication Faulted Request -
Long Protocol message.
Off
Not Powered/Not On-Line
Device is not on-line
- The device has not completed The
Dup_MAC-ID test yet
- The device may not be powered,
look at Module Status LED.
- DeviceNet Module
Status Indicator
Green
Device operational
The device is operating in a normal
condition
Summary of Contents for P9B
Page 1: ...1042936 001 Rev A January 2013 MKS Type P9B Digital Mass Flow Controller Instruction Manual...
Page 4: ......
Page 10: ...List of References vi This page intentionally left blank...
Page 20: ......
Page 22: ...12...
Page 23: ...13 MKS Instruments Inc MKS Calibration and Service Center...
Page 24: ...14...
Page 26: ...16 MKS Instruments Inc MKS MKS Calibration and Service Center...
Page 27: ...17...
Page 28: ...18...
Page 32: ......
Page 56: ...Chapter Four Analog and Digital Interface Digital Interface Input and Output Options 46...
Page 64: ......
Page 86: ...Chapter Six Embedded Web Based GUI and Diagnostics Tuning the MFC for Optional PC 76...
Page 92: ...Chapter Seven Maintenance Pressure Zero Adjustment 82 This page intentionally left blank...
Page 99: ...Troubleshooting Chart Chapter Eight Troubleshooting 89 This page intentionally left blank...
Page 100: ......
Page 105: ...Appendix A Product Specifications Electrical Specifications 95...
Page 111: ...Model Code Description 101...
Page 112: ...Model Code Description Appendix C Health and Safety Form 102 Appendix C Health and Safety Form...