Interface Cables
Chapter Two: Installation
6
Interface Cables
As of January 1, 1996, all products shipped to the European Community must comply with the
EMC Directive 89/336/EEC, which covers radio frequency emissions and immunity tests. MKS
products that meet these requirements are identified by application of the CE Mark.
This MKS product meets CE requirements, per EMC Directive 89/336/EEC. To ensure
compliance when installed, an overall metal braided shielded cable, properly grounded at both
ends, is required during use.
Standard Cables
Standard cabling is available to interface the 1152 unit with both the display set point electronics
and the power supply. Refer to Table 1 for a list of cables to attach to other MKS equipment.
Note
1. An overall metal braided shielded cable, properly grounded at both
ends, is required during use to meet CE specifications.
2. To order an overall metal braided shielded cable, add an “S” after the
cable type designation. For example, to order a standard connection
cable to connect the 1152 MFC to a 260PS-1 power supply, use part
number CB260-3-10; for an overall metal, braided, shielded cable use
part number CB260S-3-10.
Interface Cables
To Connect To . . .
Standard Cable
Metal Braided, Shielded Cable
246, 247
CB259-5-10
CB259S-5-10
647
CB147-1-10
CB147S-1-10
260PS-1/260PS-3
CB260-3-10
CB260S-3-10
Table 1: Interface Cables
For a Flow System Using All MKS Equipment
When you purchase a complete mass flow control system, specifying all companion MKS
equipment at the time of purchase, MKS will provide the appropriate cable(s) in standard lengths
for a nominal cost.
For a Flow System Using Non MKS Equipment
A shielded cable assembly, (part number CB259S-6) in a nominal 10 foot (3 m) length, with a
Type “D” connector on one end and terminated in “flying leads” (pigtail) fashion on the other
end are available from MKS.
Note
Units with flying leads are not CE compliant.