9.2.3.2
9.2.3.2 Insulation
Insulation resistance
resistance of
of the
the battery
battery
Figure 78. Measuring the insulation resistance of the battery
Figure 78. Measuring the insulation resistance of the battery
The insulation resistance of the
The insulation resistance of the disconnected
disconnected, filled
, filled and charged traction battery
and charged traction battery
mounted on the truck is at least 50
mounted on the truck is at least 50
Ω multiplied by the nominal voltage of the truck
Ω multiplied by the nominal voltage of the truck
system between the live parts and the frame of the truck. If the battery is fitted into more
system between the live parts and the frame of the truck. If the battery is fitted into more
than one containers, this test is
than one containers, this test is carried out with the electrically-connected sections
carried out with the electrically-connected sections
(including metal battery containers).
(including metal battery containers).
NOMINAL
NOMINAL
VOLTAGE
VOLTAGE
MINIMUM
MINIMUM
INSULATION
INSULATION
RESISTANCE
RESISTANCE
24 V
24 V
1,200 Ω
1,200 Ω
36 V
36 V
1,800 Ω
1,800 Ω
48 V
48 V
2,400 Ω
2,400 Ω
80 V
80 V
4,000 Ω
4,000 Ω