App - 27
Appendix 4 List of Functions Added by GT Designer2 Version Upgrade (For GOT1000 Series)
17
M
A
IN
TE
N
A
N
C
E AN
D
IN
SP
ECTIO
N
18
ERROR MESSA
GE
AND S
YSTEM
ALARM
APP
ENDICE
S
(Continued to next page)
Item
Description
Version of GT
Designer2
Version of OS
GT
15
GT Soft
GOT1000
GT
11
Advanced Alarm
Function for detecting alarm even at the
fall of bit device with Advanced User
Alarm
2.09K
Standard monitor OS [01.02.**]
Function to display a cursor by touching
an alarm and to output the corresponding
comment No. to a device.
2.43V
Standard monitor OS [03.01.**]
The binary format file output can be
converted to CSV/Unicode format file by
external control.
2.43V
Standard monitor OS [03.01.**]
Parts Display/
Parts Movement
Function for using BMP/JPEG data in
memory card as parts
2.09K
Standard monitor OS [01.02.**]
Settings for BMP/JPEG file parts can be
made on each object.
2.43V
Standard monitor OS [03.01.**]
When Bit Trigger is not met, whether to
enable "Hold Display" can be selected.
2.43V
Standard monitor OS [03.01.**]
Enables specifying the transparent color
of a figure when using an image file as a
figure.
2.47Z
Standard monitor OS [03.02.**]
Panelmeter
Windows
fonts applicable
2.09K
Standard monitor OS [01.02.**]
Stroke font applicable
2.43V
Standard monitor OS [03.01.**]
Up to 101 points can be set for scale,
value number.
2.27D
Standard monitor OS [02.04.**]
Meter Attribute and Core can be set.
2.43V
Standard monitor OS [03.01.**]
Level
When Bit Trigger is not met, whether to
enable "Hold Display" can be selected.
2.43V
Standard monitor OS [03.01.**]
Trend graph
Up to 101 points can be set for scale,
value number.
2.27D
Standard monitor OS [02.04.**]
Function to collect data only when display
trigger is met is added.
2.32J
Standard monitor OS [03.00.**]
Line graph
Up to 101 points can be set for scale,
value number.
2.27D
Standard monitor OS [02.04.**]
Function to collect data only when display
trigger is met is added.
2.32J
Standard monitor OS [03.00.**]
When Bit Trigger is not met, whether to
enable "Hold Display" can be selected.
2.43V
Standard monitor OS [03.01.**]
Bar graph
Up to 101 points can be set for scale,
value number.
2.27D
Standard monitor OS [02.04.**]
Function to collect data only when display
trigger is met is added.
2.32J
Standard monitor OS [03.00.**]
When Bit Trigger is not met, whether to
enable "Hold Display" can be selected.
2.43V
Standard monitor OS [03.01.**]
Statistics graph
Up to 101 points can be set for scale,
value number.
2.27D
Standard monitor OS [02.04.**]
Function to collect data only when display
trigger is met is added.
2.32J
Standard monitor OS [03.00.**]
When Bit Trigger is not met, whether to
enable "Hold Display" can be selected.
2.43V
Standard monitor OS [03.01.**]