18.2 List of Error Message/System Alarm
17
M
A
IN
TE
N
A
N
C
E AN
D
IN
SP
ECTIO
N
18
ERROR MESSA
GE
AND S
YSTEM
ALARM
APP
ENDICE
S
480
Communication channel not set.
Set channel number on Utility.
One or more channel for PLC and host (microcomputer) connection (Ch.1
to 5) is not allocated by GT Designer2 or utility.
Set the channel by GT Designer2 or utility.
500
Warning! Built-in battery voltage
is low.
The voltage of the GOT built-in battery is decreased.
Replace the GOT built-in battery.
510 Clock data input out of range
The value that is input as clock data is out of the input enabled range.
In this case, the input value is not accepted.
Confirm the input range of the value to be input as clock data, and input
the proper value again.
522
Unnecessary file deleted to
create new file.
Cancelled the file of different contents and created a new file.
Note that the old file is cancelled and the new file is created if the file of
the same name with different contents exists when creating files.
524
Device writing error.
Correct device.
When writing in the device, error occurred.
Correct the device.
525
Unable to read/write alarm log
files under different projects.
Unable to read the alarm log file saved by the different project.
Confirm where to store the alarm log file and alarm log file.
535 Cannot open image file.
• No CF card is installed in the drive or the access switch is turned on.
1. Install a recording medium in the specified drive.
2. Turn the access switch on.
• The specified file is not found in the card.
3. Add the image file or change the image file name to a correct one.
536
Image file error or invalid file
format.
There is an error in the image file data or the image file format is not
supported.
Change to the correct image file.
550 Invalid key code
The key code input execution trigger was ON with the non-target key code
set in the key code storage device.
Confirm the key code supported by the object where error occurs.
570 Recipe device points too large.
The number of the set points of the recipe device exceeds the specified
range.
Put the number of the set points of the recipe device within the specified
range.
571
Capacity shortage of user
memory (RAM)
There is no empty area/space in D drive.
If the alarm log file located in the D drive needs to be backed up, copy it to
the CF card with the utility and then format the D drive.
If the recipe function is used to read devices, format the D drive and then
read again to create the recipe data.