3. System remote controller
CONTROLLER
3 - 48
Contr
oller
5. Compatible Units
The TG-2000A has two main functions: centralized control of air conditioners and cost accounting. However, not all
functions are available with all air conditioners.
Table: Compatible units and function list ( : supported, : Certain restrictions apply, : Not supported)
Function
Model
Control/
Maintenance
Charging (Billing)
without WHM
Charging (Billing)
with WHM
Energy Saving
/Peak Cut
Outdoor unit
Room Air Conditioner
9
Indoor unit
LOSSNAY
Air To Water Booster unit
Air To Water HEX unit
"A" control type
"K" control type
1
6
8
2
3
1,5
1,5
4
4
(Adapter required)
HYBRID CITY MULTI
(Adapter required)
(Converter required)
1 : Can be calculated for each charging block. May not be available with some older models.
2 : Indoor unit models before Free Plan models do not support a charge apportioning billing method based on the “capacity save”. The existence of even a single unit of
those types in the system requires that the method of charge apportioning billing be set to either “Thermo on time” or “Fan operation time”.
4 : Not all of the A-control and K-control units support these functions. The calculation of the charge for the auxiliary heater may not be handled by these units.
5 :
6 : Only the function to stop the units is available.
7 : Inverter models support the outdoor unit capacity save control function.
8 : Outdoor unit Thermo-OFF control function is not supported. Only the fan speeds control function is available.
9 : Only the temperature control function or the function to stop the units is available.
10 : For the charge apportioning of Air To Water Booster unit and Air To Water HEX unit, connect the unit to individual watt-hour meter.
Although only the heating capacity is listed in the specification of Air To Water Booster unit, the "cooling" value is used for the Capacity and Power input of indoor unit
parameter for Energy-Monitoring Set Up.
The setting is already made with the cooling value for the models registered in Set-up of model name.
For Air To Water Booster unit and Air To Water HEX unit, the charging function supports only the primary refrigerant system of those units.
(Each unit obtains the reading of its watt-hour meter.)
11 : Capable of Thermo-OFF control (fan operation control) and bringing the units to stop only.
For A-control and K-control units, use the apportioned charging methods either "Thermo on time" or "Fan operation time".
Otherwise, install an watt-hour meter for each unit.
3 : LOSSNAY groups to which the remote controller is connected support the charging system.
10
10
11
11
7
(Requires separate watt
hour meters. Bills calculated
based on the reading of
each watt hour meter)
Summary of Contents for PURY-WP-YJM-A
Page 3: ...Databook ...
Page 5: ...1 2 INDOOR UNITS ...
Page 39: ...1 36 INDOOR UNITS ...
Page 51: ...1 48 INDOOR UNITS ...
Page 61: ...1 58 INDOOR UNITS ...
Page 68: ...2 1 HYBRID CITY MULTI OUTDOOR UNITS 2 OUTDOOR UNITS HYBRID CITY MULTI 2 3 ...
Page 69: ...2 2 OUTDOOR UNITS ...
Page 85: ...2 18 OUTDOOR UNITS ...
Page 172: ...4 1 HYBRID CITY MULTI SYSTEM DESIGN 4 SYSTEM DESIGN SYSTEM DESIGN 4 3 ...
Page 173: ...4 2 SYSTEM DESIGN ...