2. EXTERNAL DIMENSIONS
2 - 5
OUTDOOR UNITS
OUT
DOOR
2. EXTERNAL DIMENSIONS
2X5-ø4.6 Hole
(Make hole at the plastic fan guard
for snow hood attachment)
150
150
150
150
80
18
18
11
84
*1
*1
*1
PUR
Y-WP250YJM
ø19.05 Brazed
ø22.2 Brazed
84
94
301
83
271
150
251
75
58
271
77
90
217
146
235
2
4
5
7
140
Front through hole
Bottom through hole
Front through hole
Front through hole
Bottom through hole
Front through hole
Usage
For transmission cables
For wires
For pipes
NO.
Front through hole (Uses when twinning kit (optional
parts) is mounted.)
ø65 Knockout hole
150X94 Knockout hole
140X77 Knockout hole
Specifications
ø65 or ø40 Knockout hole
ø52 or ø27 Knockout hole
ø34 Knockout hole
ø45 Knockout hole
(front and back,2 points)
Note 2*
Note 1.Please refer to the next page for information
regarding necessary spacing around the
unit and foundation work.
2.The detachable leg can be removed at site.
3.At brazing of pipes,wrap the refrigerant service
valve with wet cloth and keep the temperature of
refrigerant service valve under 120°C.
<Accessories>
Connecting pipe
<Low pressure> · Elbow(IDø19.05XΟDø19.05) · · ·WP200 1 pc.
· Pipe(IDø25.4XODø19.05)
·
·
·
·
·WP200 1 pc.
· Pipe(IDø25.4XIDø22.2)
·
·
· ·
·
·
·WP250 1 pc.
<High pressure>
· E
lb
o
w
(I
D
ø
1
5
.8
8
X
ID
ø
1
5
.8
8) · · ·WP200 1 pc.
· Elbow(IDø19.05XΟDø19.05) · · ·WP250 1 pc.
· Pipe(IDø25.4XODø15.88)
·
·
·
·
·WP200 1 pc.
· Pipe(IDø25.4XODø19.05)
·
·
·
·
·WP250 1 pc.
55
*1.Connect by using the connecting pipes (for bottom piping and front piping)
that are supplied.
*1
3
6
Refrigerant service
valve <High pressure>
1
77
90
Detachable leg
760
60
55
60
(60)
(Mounting pitch)
2X2-14X20 Oval hole
(Mounting pitch)
Refrigerant service
valve <Low pressure>
Refrigerant service
valve <High pressure>
Refrigerant service
valve <Low pressure>
ø19.05 Brazed
Low
pressure
Connection specifications for
the refrigerant service valve
High
pressure
ø15.88 Brazed
PUR
Y-WP200YJM
Model
Connecting pipe specifications
(60)
1710
1220
760
1650
240
1410
216
18
724(721~727)
80
80
1060
18
Intake
air
Control box
Intake
air
Service panel
131
(760)
Discharge air
Intake
air
54
25
25
145
263
145
<Snow hood attachment hole>
Left side view
Top view
Front view
Bottom view
1
2
4
3
5
6
7
PURY-WP200,250YJM-A
Unit : mm
Summary of Contents for PURY-WP-YJM-A
Page 3: ...Databook ...
Page 5: ...1 2 INDOOR UNITS ...
Page 39: ...1 36 INDOOR UNITS ...
Page 51: ...1 48 INDOOR UNITS ...
Page 61: ...1 58 INDOOR UNITS ...
Page 68: ...2 1 HYBRID CITY MULTI OUTDOOR UNITS 2 OUTDOOR UNITS HYBRID CITY MULTI 2 3 ...
Page 69: ...2 2 OUTDOOR UNITS ...
Page 85: ...2 18 OUTDOOR UNITS ...
Page 172: ...4 1 HYBRID CITY MULTI SYSTEM DESIGN 4 SYSTEM DESIGN SYSTEM DESIGN 4 3 ...
Page 173: ...4 2 SYSTEM DESIGN ...