1. MITSUBISHI ELECTRIC's Air-conditioner Network System. (MELANS)
3 - 3
CONTROLLER
Controller
1-1. Function table of controllers
*1. Group setting via wiring between Indoor units with cross-over cable;
*2. Installation possible at Initial setting web browser;
*3. Inter-lock is set at Local remote controller.
*4. AG-150A/GB-50ADA license registration to AG-150A/GB-50ADA is required to monitor and operate the units by browser and TG-2000A.
*5. AG-150A connected with PAC-YG50ECA is compatible with TG-2000A Ver.6.1* or later. GB-50ADA is compatible with TG-2000A Ver. 6.3* or later.
*6. This function can be set only on the ME/Simple ME remote controller. This function cannot be used with the MA/Simple MA remote controller.
(But, the validity of this function with the MA/Simple MA remote controller depends on the indoor unit model, and there are possibilities that this function can be used with them.)
*7. This function is available only when applying together with TG-2000A, AG-150A and GB-50ADA.
*8. Inter-lock is set from system controller. (Except PAC-YT40ANRA)
*9. The maximum number of controllable units decreases depending on the indoor unit model.
*10. For indoor use only.
Model
Controllable Groups / Indoors
(Group / Indoor)
Local remote controller
*10
*10
*9
*4
System controller
■Operating
ON / OFF
Mode (cool / heat / dry / fan)
Temperature-set
Local Permit / Prohibit
Fan speed
Air-flow direction
■Status monitoring
ON / OFF
Mode (cool / heat / dry / fan)
Temperature-set
Local Permit / Prohibit
Fan speed
Air-flow direction
Indoor temperature
Filter sign
Error flashing
Error code
Operation hour
■Scheduling
One-day
Times of ON / OFF per day
Weekly
Times of ON / OFF per week
Annual
Optimized start-up
Auto-off timer
Min. timer setting unit (minute)
■Recording
Error record
Daily / monthly report
Electricity charge
■Other
Temp-set limitation by Local R / C
Temp-set limitation by System controller
Operation-lock
Night setback
Sliding temperature control
■Management (Group / Interlocked)
Ventilation interlock
Group setting
Block setting
Revision of electricity charge
■Operating on LOSSNAY interlocked (Group / Interlocked)
ON / OFF
Fan speed
Ventilation mode
■Status monitoring on LOSSNAY interlocked (Group / Interlocked)
ON / OFF
Fan speed
Ventilation mode
PAR-
FL32MA
1 / 16
N
N
N
10
N
N
N
1 / 1
N
N
N
N
N
N
N
N
N
N
N
N /
N
N
N
N
N
N
N
N
N
N
N
PAC-
SE51CRA
1 / 16
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N /
N
N /
N
N
N
N
N
N
N
PAC-
YT40ANRA
16 / 50
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
/
*3
N
N
N
N
N
N
N
AG-150A
50 / 50
AG-150A Browser
*4
*2 *6
N
N
N
1
24 x 7
24
( )
( )
N
1
24 x 7
24
N
N
N
N
/
/
/ N
/
/ N
/
/
/ N
/
/
/
/ N
*2
*2
*2
*2
*2
N
/
N
N
N
N
N
N
PAR-
F27MEA
1 / 16
N
N
10
N
N
N
1 / 1
N
N
N
N
N
N
N
N /
N
N
N
N
N /
N
N
PAR-
21MAA
1 / 16
*6
*1
N
N
N
1
N
8 x 7
8
N
N
N
N /
N
N /
N /
N / N
N /
N
N
N /
N
N
PAR-
31MAA
1 / 16
*6
*1
N
N
N
5
N
8 x 7
1
N
N
N /
N
N /
N /
N / N
N /
N
N
N /
N
AT-50A
50 / 50
N
N
N
5
N
16 x 7
16
N
N
/
/ N
/
/
/
/ N
N
N
N
N
*6
: Each group / Batched ;
: Each group ;
: Block
: AG-150A / GB-50ADA license registration possible.
N : Not Available (Not Used.)
( ) : License registration for the optional functions required
: Batched only ;
: Batched handling (for maintenance)
04-E L
ON
W
ORKS
( )
AG-150A +
PAC-YG50ECA
AG-150A Browser
*4
150 / 150
N
N
N
1
24 x 7
24
N
1
24 x 7
24
N
N
N
N
/
/ N
/
/
/ N
/
/
/
/ N
/
/
/ N
*2
*2
*2
*2
*2
N
/
N
N
N
N
*2 *6
N
N
( )
*2
*2
*2
*2
*2
GB-50ADA
GB-50ADA Browser
*4
50 / 50
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
1
24 x 7
24
N
N
N
N
N
/
N / N
N / N
/
/ N
/
/
N / N
N / N
/
/
/ N
N
/
N
N
N
N
N
N
N
N
N
*2 *6
N
N
( )
TG-2000A
*4 *5
2000 / 2000
N
1
24 x 7
24
/
/ N
/
/
/
/ N
/
N
*6
N
N
( )
*7
*8
PAC-
YT52CRA
1 / 16
*6
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N /
N
N
*1
N
N
N /
N
N
N /
Summary of Contents for PURY-WP-YJM-A
Page 3: ...Databook ...
Page 5: ...1 2 INDOOR UNITS ...
Page 39: ...1 36 INDOOR UNITS ...
Page 51: ...1 48 INDOOR UNITS ...
Page 61: ...1 58 INDOOR UNITS ...
Page 68: ...2 1 HYBRID CITY MULTI OUTDOOR UNITS 2 OUTDOOR UNITS HYBRID CITY MULTI 2 3 ...
Page 69: ...2 2 OUTDOOR UNITS ...
Page 85: ...2 18 OUTDOOR UNITS ...
Page 172: ...4 1 HYBRID CITY MULTI SYSTEM DESIGN 4 SYSTEM DESIGN SYSTEM DESIGN 4 3 ...
Page 173: ...4 2 SYSTEM DESIGN ...