- 198 -
SW1
LED
No.
1234567890
Item
LD1
LD2
LD3
LD4
LD5
LD6
LD7
LD8
Remarks
0
0000000000
1
1000000000
2
0100000000
3
1100000000
4
0010000000
5
1010000000
6
0110000000
7
1110000000
8
0001000000
9
1001000000
10 0101000000
11 1101000000
12 0011000000
13 1011000000
14 0111000000
15 1111000000
16 0000100000
17 1000100000
18 0100100000
19 1100100000
20 0010100000
21 1010100000
22 0110100000
23 1110100000
24 0001100000
25 1001100000
26 0101100000
27 1101100000
28 0011100000
29 1011100000
Comp
operation
Comp 1
operation
Comp 2
operation
Lights for
normal
operation
52C1
52C2
0000 ~ 9999
(Address and error code reversed)
0000 ~ 9999
(Address and error code reversed)
0000 ~ 9999
(Address and error code reversed)
0000 ~ 9999
0000 ~ 9999
SV1
SV2
SV5b
SV5a
52F
SV3
SV4a
SV4b
SV4d
SV4c
21S4a
21S4b
CH11
CH12
Retry
operation
Temporary
operation
Contact
demand
Night
mode
Cooling and
heating
mode
selection
(Cooling)
Cooling and
heating
mode
selection
(Heating)
Snow
sensor
Unit No.1
Unit No.2
Unit No.3
Unit No.4
Unit No.5
Unit No.6
Unit No.7
Unit No.8
Unit No.9
Unit No.10 Unit No.11 Unit No.12 Unit No.13 Unit No.14 Unit No.15 Unit No.16
Unit No.17 Unit No.18 Unit No.19 Unit No.20 Unit No.21 Unit No.22 Unit No.23 Unit No.24
Unit No.25 Unit No.26 Unit No.27 Unit No.28 Unit No.29 Unit No.30 Unit No.31 Unit No.32
Unit No.1
Unit No.2
Unit No.3
Unit No.4
Unit No.5
Unit No.6
Unit No.7
Unit No.8
Unit No.9
Unit No.10 Unit No.11 Unit No.12 Unit No.13 Unit No.14 Unit No.15 Unit No.16
Unit No.17 Unit No.18 Unit No.19 Unit No.20 Unit No.21 Unit No.22 Unit No.23 Unit No.24
Unit No.25 Unit No.26 Unit No.27 Unit No.28 Unit No.29 Unit No.30 Unit No.31 Unit No.32
Relay output display 1
(lighting to display)
Check display 1
OC error
Check display 2
OC preliminary error
Check code 3
(including IC and BC)
Relay output
display 2
Relay output
display 3
Relay output
display 4
Special operation
Communication
demand capacity
Contact demand
capacity
External signal
[signal during input]
Warm up
mode
3 minutes
restart
protection
mode
Compressor
operation
BC
operation
Preliminary
error
Error
3 minutes
restart afte
instanta-
neous po-
wer failure
Vacuum
operation
protection
delayed
Outdoor unit
operation display
Indoor unit check
Indoor unit operation
mode
LD8 is a relay output
which lights up at all
times when the
microcomputers power
is on.
Lights up during
cooling.
Blinks during heating.
Goes off during stop
and blower mode.
If the IC makes an
error stop, lit up Unit
No.1
can be lit out with error
rest in order from small
address.
If no demand control,
"----" is diaplayed [ % ].
If no demand control,
"----" is diaplayed [ % ].
Display the latest preli-
minary error.
If there is no error,
"----" is displayed.
If there is no
error "----" is displayed.
LED monitor display
4. List of code on the LED monitor