Name
Notes
Function
Specification
Check method
Symbol
(function)
1
273+t
Compres-
sor
High
-pressure
sensor
Pressure
switch
Thermistor
MC1
MC2
63HS
P450-P650
types only
R
120
=7.465k
Ω
R
25/120
=4057
Rt =
7.465exp{4057( - )}
Resistance value
check
Resistance value
check
1
393
1
273+t
R
0
=15k
Ω
R
0/80
=3460
Rt =
15exp{3460( - )}
1
273
Pressure
0~4.15MPa
Vout 0.5~3.5V
0.071V/0.098MPa
Pressure [MPa]
=1.38
✕
Vout[V]-0.69
Gnd (Black)
Vout (White)
Vcc (DC5V) (red)
Con-
nector
63HS
1
1 2 3
2
3
Adjusts the volume of circulating re-
frigerant by controlling the operating
frequency with the operating pres-
sure.
Secures a constant amount of circu-
lating refrigerant when the operating
load exceeds MC1 s ability to control
the refrigerant amount.
(P200-type)
High-pressure shell scroll type
Winding resistance
20˚C : 0.72
Ω
(P250-P400 types)
Low-pressure shell scroll type
Winding resistance
20˚C : 0.583
Ω
Low-pressure shell scroll type
Winding resistance
20˚C : 1.981
Ω
63H1
63H2
TH11, 12
(Discharge)
TH5
(Piping temp-
erature)
TH6
(Outdoor air
temperature)
TH7
THHS
Inverter
heat sink
temperature
Heat sink
63H2 on P450
-P650 types only
TH12 on
P450-P650
types only
1
Detects high pressure
2
Protects high pressure
Controls defrost during heating
operation
1
Detects discharge temperature
2
Protects high pressure
1
Detects outdoor temperature
2
Controls fan operation
Controls defrost during heating
operation
Controls inverter cooling fan, using
THHS temperature.
0˚C : 698k
Ω
60˚C : 48k
Ω
10˚C : 413k
Ω
70˚C : 34k
Ω
20˚C : 250k
Ω
80˚C : 24k
Ω
30˚C : 160k
Ω
90˚C : 17.5k
Ω
40˚C : 104k
Ω
100˚C : 13.0k
Ω
50˚C : 70k
Ω
110˚C : 9.8k
Ω
0˚C : 15k
Ω
25˚C : 5.3k
Ω
10˚C : 9.7k
Ω
30˚C : 4.3k
Ω
20˚C : 6.4k
Ω
40˚C : 3.1k
Ω
1
273+t
R
0
=17k
Ω
R
25/120
=4170
Rt =
17exp{4170( - )}
1
323
0˚C : 181k
Ω
25˚C : 50k
Ω
10˚C : 105k
Ω
30˚C : 40k
Ω
20˚C : 64k
Ω
40˚C : 26k
Ω
4.15MPa Set to OFF
1
Detects high pressure
2
Regulates frequency and protects
high pressure.
Low
-pressure
sensor
63LS
Pressure
0~1.7MPa
Vout 0.5~3.5V
0.173V/0.098MPa
Pressure [MPa]
=0.566
✕
Vout[V]-0.283
Gnd (Black)
Vout (White)
Vcc (DC5V) (red)
Con-
nector
63LS
1
1 2 3
2
3
1
Detects low-pressure
2
Protects low-pressure
- 82 -
[2]
Functions of Principal Parts
1. Outdoor Unit