126
15-4. Different-diameter pipe
Unit : inch
For different-
diameter
pipes
MXZ30TN
MXZ30TN2
MAC-454JP
MAC-455JP
MAC-456JP
Model name
51H-454
51H-455
516456
Model code
Connected
pipes diameter
Size
A
2 3/4
2 9/16
2 5/8
Size
B
3/8
1/2
1/2
1/2
3/8
5/8
Size
C
3/8 - 1/2
1/2 - 3/8
1/2 - 5/8
B
A
C
15
Air cleanig filter (White bellows type)
15-2. AIR CLEANING FILTER
●
AIR CLEANING FILTER removes fine dust of 0.01 micron from air by means of static electricity.
●
Normal life of AIR CLEANING FILTER is 4 months. However, when it becomes dirty, replace it as soon as possible.
●
Clogged AIR CLEANING FILTER may reduce the air conditioner capacity or cause frost on the air outlet.
●
DO NOT reuse AIR CLEANING FILTER even if it is washed.
●
DO NOT remove or attach AIR CLEANING FILTER during unit operation.
15-3. DEODORIZING FILTER
●
DEODORIZING FILTER removes ammonia and hydrogen sulphide emitted from tobacco, and odor of pets.
●
Clean DEODORIZING FILTER every two weeks. If the filter is particularly dirty, clean the filter more often.
●
For cleaning, soak the filter in warm water for a while, and then wash and rinse it. Dry the filter in the shade
thoroughly.
●
When the filter color is still dark even after cleaning, replace the filter with a new one.
Replace the filter at least once a year.
●
DEODORIZING FILTER and AIR CLEANING FILTER can be attached on either side.
Deodorizing filter (Gray sponge type)
Pipe length
Cross-
section
Part No.
Model
A-Gas(in.)
B-Liquid(in.)
Pipe size
Insulation
(in.)
Additional
refrigerant
charge
R22(oz.)
MSH12TN MSH12TN -
U1
Outside
diameter
Wall
thickness
Outside
diameter
Wall
thickness
MSH09TW MSH09TW -
U1
MUH09TW MUH09TW -
U1
MUH12TN MUH12TN -
U1
MUH12TN -
U2
MSH15TN MSH15TN -
U1
MUH15TN MUH15TN -
U1
MUH15TN -
U2
MSH17TN MSH17TN -
U1
MUH17TN MUH17TN -
U1
10ft.
16ft.
23ft.
33ft.
49ft.
10ft.
16ft.
23ft.
33ft.
49ft.
10ft.
16ft.
23ft.
33ft.
49ft.
C 1-3/8
C 1-7/32
D 1-1/16
C 1-11/32
D 1-1/16
MAC-645PI
MAC-646PI
MAC-647PI
MAC-648PI
MAC-649PI
MAC-660PI-US
MAC-661PI-US
MAC-662PI-US
MAC-663PI-US
MAC-664PI-US
MAC-725PI
MAC-726PI
MAC-727PI
MAC-728PI
MAC-729PI
0
4.29
12.86
0
4.29
12.86
0
4.29
12.86
3/8
1/2
5/8
0.03
1/4
0.03
0.04
,
,
,
,
,
15-1. REFRIGERANT PIPES
The air conditioner has flared connections its on indoor and outdoor sides.
Please use the optional extension pipe as follows.
Model
Part No.
MAC-1300FT
MSH09TW MSH09TW -
U1
MAC-1100FT
MSH12TN MSH15TN MSH17TN
MSH12TN -
U1
MSH15TN -
U1
MSH17TN -
U1
Model
Part No.
MAC-1800DF
MSH09TW MSH09TW -
U1
MAC-1600DF
MSH12TN MSH15TN MSH17TN
MSH12TN -
U1
MSH15TN -
U1
MSH17TN -
U1
OPTIONAL PARTS
OB275--5.qxp 03.12.2 5:31 PM Page 126
Summary of Contents for MSH09TW
Page 127: ......