Summary of Contents for RAC-24CP6

Page 1: ... of trouble free use please read this instruction manual completely ULOKF VO Ÿö Þù V VDŽ ÊËbÐ WK uÞ b UN ULF Ý sJ1 wJ Æ bOł VO J c vKŽ SPLIT TYPE INDOOR UNIT OUTDOOR UNIT MODEL RAS 24CP6 RAC 24CP6 INDOOR UNIT OUTDOOR UNIT RAC 24CP6 RAS 24CP6 Untitled 3 20 1 06 05 50 PM 1 Black ...

Page 2: ...on where there is flammable gas The outdoor unit may catch fire if flammable gas leaks around it Please ensure smooth flow of water when installing the drain hose CAUTION PRECAUTIONS DURING SHIFTING OR MAINTENANCE PRECAUTIONS DURING OPERATION Avoid an extended period of direct air flow for your health W A R N I N G Should abnormal situation arises like burning smell please stop operating the unit ...

Page 3: ...se on the air deflector and drips down occasionally This will wet your furniture Therefore do not operate under such condition for a long time If the amount of heat in the room is above the cooling or heating capability of the unit for example more people entering the room using heating equipments and etc the preset room temperature cannot be achieved This appliance is not intended for use by youn...

Page 4: ...r Vertical deflector Air Outlet Refer page 11 Remote controller Send out operation signal to the indoor unit So as to operate the whole unit Refer page 6 OUTDOOR UNIT Drain pipe Condensed water drain to outside Connecting cord and insulation pipe for piping Air inlet Back and Left side Air outlet WIDTH mm 1030 850 MODEL RAS 24CP6 RAC 24CP6 HEIGHT mm 295 650 DEPTH mm 190 298 MODEL NAME AND DIMENSIO...

Page 5: ...CATOR This figure shows the opening condition of front panel Refer to page 19 in relation to how to open or close the front panel OPERATION LAMP This lamp lights during operation TIMER LAMP This lamp lights when the timer is working FILTER LAMP When the device is operated for a total of about 200 hours the FILTER lamp lights to indicate that it is time to clean the filter The lamp goes out when th...

Page 6: ... TIMER button Select the turn OFF time ON TIMER button Select the turn ON time TIME button Use this button to set and check the time and date RESET button FUNCTION selector Use this button to select the operating mode Every time you press it the mode will change from AUTO to COOL to DEHUMIDIFY to CIRCULATION and to FAN cyclically FAN SPEED selector This determines the fan speed Every time you pres...

Page 7: ...starts with a beep Press the button again to stop operation You can raise or lower the temperature setting as necessary by maximum of 3 C Press the temperature button and the temperature setting will change by 1 C each time The preset temperature and the actual room temperature may vary somewhat depending on conditions The display does not indicate the preset temperature in the AUTO mode If you ch...

Page 8: ... become cool quickly MED Quiet LOW More quiet Set the desired room temperature with the TEMPERATURE button the display indicates the setting The range of 25 28 C is recommended as the room temperature for cooling If the temperature setting is 27 C the room temperature will be controlled at around 27 C The temperature setting and the actual room temperature may vary some how depending on conditions...

Page 9: ...ture setting The function will stop the indoor unit will stop emitting air as soon as the room temperature becomes lower than the setting temperature Set the desired room temperature with the TEMPERATURE button the display indicates the setting The range of 20 26 C is recommended as the room temperature for dehumidifying Press the START STOP button Dehumidifying operation starts with a beep Press ...

Page 10: ...D button Press the START STOP button Fan operation starts with a beep Press the button again to stop operation 1 2 START STOP Note In the fan operation mode only display of FAN SPEED setting will change by pressing FAN SPEED button the actual fan speed cannot be changed directly from HI to LOW mode CIRCULATION OPERATION Press the FUNCTION selector so that the display indicates CIRCULATE Press the ...

Page 11: ... stops at the position where the air outlet closes When cooling dehumidifying CAUTION In Cooling operation do not keep the horizontal air deflector swinging for a long time Some dew may form on the horizontal air deflector and dew may drop Adjustment of the conditioned air in the upward and downward directions The horizontal air deflector is automatically set to the proper angle suitable for each ...

Page 12: ...e RESERVED sign goes out with a beep and the TIMER lamp turns off on the indoor unit 1 Set the current month and day with the TIMER control button 1 Press the OFF TIMER button The OFF mark blinks on the display 1 Press the ON TIMER button the ON mark blinks on the display 2 Set the turn off time with the TIMER control button Press the RESERVE button 3 Press the ON TIMER button so that the OFF mark...

Page 13: ...le The device will turn off at 11 00p m Example The device will automatically turn on earlier so that the preset temperature can be reached at 7 00 a m The setting of the turn on time is now complete 4Set the turn on time with the TIMER control button 5 Point the signal window of the remote controller toward the indoor unit and press the RESERVE button The ON mark starts lighting instead of flashi...

Page 14: ...e controller The TIMER lamp lights with a beep from the indoor unit When the sleep timer has been set the display indicates the turn off time Example If you set 3 hours sleep time at 11 38 p m the turn off time is 2 38 a m 2 Press the SLEEP button and set the sleep timer The device will be turned off by the sleep timer and turned on by on timer How to Cancel Reservation Point the signal window of ...

Page 15: ... varied The room temperature will be controlled 2 C above the temperature and the FAN SPEED will be set to LOW setting 1 hour after the setting of the sleep timer Fan Operation with the sleep timer If date or current time is not set sleep timer can not be set If you set the sleep timer after the off on off or off on timer has been set the sleep timer becomes effective instead of the off on off or ...

Page 16: ...2 Install the new batteries The direction of the batteries should match the marks in the case 1 Do not use new and old batteries or different kinds of batteries together 2 Take out the batteries when you do not use the remote controller for 2 or 3 months CAUTION Push and pull to the direction of arrow Untitled 5 20 1 06 05 56 PM 16 ...

Page 17: ...ake up time in the morning This will enable you to enjoy a comfortable room temperature Please use the timer effectively Dusty air filter will reduce the air volume and the cooling efficiency To prevent from wasting electric energy please clean the filter every 2 weeks Please pay attention to the room temperature and air flow direction when operating the unit for baby children and old folks who ha...

Page 18: ... consumes about 8W in the operation control circuit even if it is in OFF mode Warning To protect the whole unit during lightning please stop operating the unit and remove the plug from the socket OFF Interference From Electrical Products Inverter type fluorescent lamp To prevent interference place at least 1m away TV Caution To avoid noise interference please place the indoor unit and its remote c...

Page 19: ...y by qualified service personal Before cleaning stop operation and switch off the power supply CAUTION CAUTION Do not bend the air cleansing filter as it may cause damage to the structure NOTE In case of removing the air cleansing filters please follow the above procedures The cooling capacity is slightly weakened and the cooling speed becomes slower when the air cleansing filters are used So set ...

Page 20: ... soft bristle brush Allow filters to dry in shade 3 Re insert the air cleansing filter to the filter frame Set the filter with FRONT mark facing front and slot them into the original state After attaching the filters push the front panel at three arrow portions as shown in figure and close it CAUTION Do not wash with hot water at more than 40 C The filter may shrink When washing it shake off moist...

Page 21: ... this may cause short circuit Never use hot water above 40 C benzine gasoline acid thinner or a brush because they will damage the plastic surface and the coating Removing the Front Panel Arm When the front panel is fully opened with both hands push the right arm to the inside to release it and while closing the front panel slightly put it out forward Attaching the Front Panel Move the projections...

Page 22: ...talled depending on the mounting site of the unit Without a circuit breaker the danger of electric shock exists IMPORTANT The wires in this mains lead are coloured in accordance with the following code Green and yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug pr...

Page 23: ...room air conditioner because the various odor emitted by smoke foodstuffs cosmetics and so on sticks to it So the air filter and the evaporator regularly must be cleaned to reduce the odor Please contact your sales agent immediately if the air conditioner still fails to operate normally after the above inspections Inform your agent of the model of your unit production number date of installation P...

Page 24: ...igned for use within certain voltage limits Minimum Maximum Indoor Dry bulb C 21 32 Wet bulb C 15 23 Outdoor Dry bulb C 21 52 Wet bulb C 15 31 Note Avoid to use the room air conditioner for cooling operation when the outside temperature is below 21 C 70 F The recommended maximum and minimum operating temperatures of the hot and cold sides should be as below Untitled 5 20 1 06 05 56 PM 24 ...