63
Press once
<Cool>
Press again
<Heat>
Press once again
<Stop>
OPERATION INDICATOR lamp
EMERGENCY OPERATION
switch
MSH09TW MSH09TW -
U1
EMERGENCY OPERATION
switch
MSH12TN MSH12TN -
MSH15TN MSH15TN -
MSH17TN MSH17TN -
U1
U1
U1
• The following indication applies regardless of shape
of the indicator.
10-8. EMERGENCY-TEST OPERATION
In case of test run operation or emergency operation, use the EMERGENCY OPERATION switch on the front of the
indoor unit. Emergency operation is available when the remote controller is missing, has failed or the batteries of remote
controller run down. The unit will start and the OPERATION INDICATOR lamp will light.
The first 30 minutes of operation is the test run operation. This operation is for servicing. The indoor fan speed runs at
High speed and the system is in continuous operation. (The thermostat is ON.)
After 30 minutes of test run operation the system shifts to EMERGENCY COOL/HEAT MODE with a set temperature of
75˚F.
The fan speed shifts to Med. speed.
The coil frost prevention works even in emergency operation, and defrosting cycle as well.
In the test run or emergency operation, the horizontal vane operates in VANE AUTO (
) mode.
Emergency operation continues until the EMERGENCY OPERATION switch is pressed once or twice or the unit receives
any signal from the remote controller. In case of latter normal operation will start.
NOTE : Do not press the EMERGENCY OPERATION switch during normal operation.