30
Capacity
SHF
Input
Outdoor unit
Power supply (V, phase, Hz)
Input
Comp. current
Fan motor current
Condensing pressure
Suction pressure
Discharge temperature
Condensing temperature
Suction temperature
Comp. shell bottom temp
Ref. pipe length
[Total pipe length for multi-system]
Refrigerant charge (R22)
Intake air temperature
Fan speed (208/230V)
Airflow (208/230V)
Unit
Btu / h
—
kW
kW
A
A
PSIG
PSIG
˚F
˚F
˚F
˚F
ft.
—
˚F
˚F
rpm
CFM
Heating
28,600
–
2.8
2.8
12.3
219
47
169
26
144
47
43
DB
WB
Item
Model
Total
Electrical
circuit
Refrigerant
circuit
Outdoor
unit
Cooling
28,400
–
3.8
3.8
17.1
300
65
194
41
150
95
–
MXZ30TN MXZ30TN2
208/230, 1, 60
0.60
127
82 [197]
8 lb. 10 oz.
630/675
1,764/1,906
MXZ30TN MXZ30TN2
INDOOR UNIT
MXZ30TN
MXZ30TN2
115V 60Hz
1
[
, 2 wires
208/230V 60Hz 1
[
,
2 wires
SIGNAL WIRE
2 wires 12V DC
INDOOR UNIT
INDOOR UNIT
115V 60Hz
1
[
, 2 wires
115V 60Hz
1
[
, 2 wires
✻
Control voltage
Power supply voltage to serial
signal circuit is 12V DC.
Peak voltage between
1
1
-
and
3
3
+ on in-out terminal
block is 12V DC .
POWER SUPPLY
OB275--1.qxp 03.12.2 16:49 Page 30