REFRIGERANT SYSTEM DIAGRAM
9
Unit:inch
MSH09TW MSH09TW -
U1
INDOOR UNIT
OUTDOOR UNIT
(with heat insulator)
(with heat insulator)
Refrigerant pipe
[
3/8
(Option)
4-way
valve
Muffler
Stop valve
(with service
port)
Strainer
Refrigerant pipe
[
1/4
(Option)
Stop valve
Capillary tube CT2
O.D. 0.12
✕
I.D.
0.063
✕
17-11/16
Check
valve
R.V. coil
heating ON
cooling OFF
Flow of refrigerant (cooling)
Flow of refrigerant (heating)
Defrost
thermistor
RT61
Outdoor
heat
exchanger
Room temperature
thermistor
RT11
Indoor coil
thermistor
RT12
Capillary tube CT1
O.D. 0.12
✕
I.D. 0.055
✕
19-11/16
Flared connection
Flared connection
Compressor
Indoor
heat
Strainer
MSH12TN
INDOOR UNIT
OUTDOOR UNIT
Indoor
heat
exchanger
Room temperature
thermistor
RT11
Refrigerant pipe
[
1/2
(Option)
Flared connection
Flared connection
Indoor coil
thermistor
RT12
Refrigerant pipe
[
1/4
(Option)
(with heat insulator)
Stop valve
Strainer
Capillary tube CT1
O.D. 0.12
✕
I.D.0.071
✕
11-13/16
Compressor
Stop valve
(with service
port)
Muffler
Outdoor
heat
exchanger
Defrost
thermistor
RT61
R.V.
coil
heating ON
cooling OFF
Flow of refrigerant (cooling)
Flow of refrigerant (heating)
(with heat insulator)
Distributor
4-way
valve
Unit:inch
exchanger
Service
port
Fusible
plug
Service
port
Muffler
Fusible
plug
Service
port
Service
port
Capillary tube CT1
O.D. 0.12
✕
I.D.
0.055
✕
19-11/16
Muffler
Capillary tube CT3
O.D. 0.12
✕
I.D.
0.063
✕
31-1/2
MUH09TW MUH09TW -
U1
MUH12TN
MSH12TN
-
U1
MUH12TN -
U1
Strainer
MUH12TN -
U2
OB275--2.qxp 03.12.2 16:50 Page 51