111
OPERATING PROCEDURE
PHOTOS
4. Removing the heat exchanger and compressor
(1) Remove the screws of the rear panel. Remove the screws
of the valve bed and the valve bed. (The valve bed is fixed
by the catches on the right and left sides. Lift it to remove.)
Open the rear panel to the rear to remove.
NOTE :
All panels are fixed by catches, and must be removed by
up and down.
(2) Remove the screws of the side panel and the side panel.
(3) Remove the screws of the rear guard and the rear guard.
(4) Remove the screws of the separator support plate and
the separator support plate.
(5) Remove the screws of the motor support and the motor
support.
(6) Remove the relay panel.
Disconnect the fan motor lead wires.
(7) Remove the soundproof felt.
(8) Remove the screws of the separator and the separator.
(9) Recover gas from the refrigerant circuit.
(10) Remove the screws of the heat exchanger and the heat
exchanger.
Detach the welded part of pipe.
(11) Remove the nuts of the compressor and the compressor.
Detach the welded part of the suction pipe and the discharge
pipe.
NOTE
●
Before using the torch, reclaim gas from the pipes until the
pressure gauge shows 0 PSIG.
●
Use the torch under the condition that gas can be recovered
even when the inner pressure rises by heat.
●
Reclaim all refrigerant in an environmentally acceptable man-
ner.
Screws
Screws
Photo 5
Heat exchanger
Accumulator
Photo 6
Photo 7
Rear
panel
Rear guard
Side
panel
Stop valve
Compressor
Sound proof
felt
Service port