1. FUNCTIONS AND CONFIGURATION
1.2 Servo amplifier standard specifications
Servo amplifier
Item
MR-J2-03B5
Voltage
21.6 to 30VDC (instantaneous permissible voltage 34V)
HC-AQ0135D
Continuous 0.8A, max. 2.4A
HC-AQ0235D
Continuous 1.6A, max. 4.8A
Circuit
power
supply
(Note)
Power supply
capacity
HC-AQ0335D
Continuous 2.4A, max. 7.2A
Control circuit power supply
(Note)
24VDC 10% 200mA (400mA when using the servo motor equipped with electromagnetic
brake)
System
Sine-wave PWM control, current control system
Dynamic brake
Built-in
Protective functions
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic
thermal relay), servo motor overheat protection, encoder fault protection, undervoltage,
instantaneous power failure protection, overspeed protection, excessive error protection
Speed frequency response
250Hz or more
Structure
Open (IP00)
[ ]
0 to 55 (non-freezing)
Operation
[ ]
32 to 131 (non-freezing)
[ ]
20 to 65 (non-freezing)
Ambient
temperature
Storage
[ ]
4 to 149 (non-freezing)
Operation
Ambient
humidity
Storage
90%RH or less (non-condensing)
Ambient
Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude
Max. 1000m (3280ft) above sea level
[m/s
2
]
5.9 or less
En
vi
ro
nm
en
t
Vibration
[ft/s
2
]
19.4 or less
[kg]
0.2
Weight
[lb]
0.44
Note: To comply with the low voltage directive, use a reinforced insulation stabilizing power supply.
1.3 Function list
The following table lists the functions of this servo. For details of the functions, refer to the reference field.
Function
Description
Reference
Slight vibration suppression
control
Suppresses vibration of 1 pulse produced at a servo motor stop.
Section 6.5
Real-time auto tuning
Automatically adjusts the gain to optimum value if load applied to the servo
motor shaft varies.
Section 6.2
Section 6.3
Parameter No.9
Torque limit
Servo motor torque can be limited to any value.
Parameter No.10
Parameter No.11
External forced stop signal
automatic ON
Forced stop (EM1) can be automatically switched on internally to invalidate it. Parameter No.23
Test operation mode
Servo motor can be run from the operation section of the servo amplifier
without the start signal entered.
Section 4.4
Servo configuration software
Using a personal computer, parameter setting, test operation, status display,
etc. can be performed.
Section 11.1.2
Summary of Contents for MR-J2-03B5
Page 11: ...A 10 MEMO ...
Page 15: ...4 MEMO ...
Page 21: ...1 6 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 27: ...2 6 2 INSTALLATION MEMO ...
Page 61: ...5 8 5 PARAMETERS MEMO ...
Page 73: ...7 2 7 INSPECTION MEMO ...
Page 81: ...8 8 8 TROUBLESHOOTING MEMO ...
Page 87: ...9 6 9 OUTLINE DIMENSION DRAWINGS MEMO ...
Page 91: ...10 4 10 CHARACTERISTICS MEMO ...
Page 111: ...11 20 11 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...