Appendix 2 Standards
Requirements for Low Voltage Directive (LVD) compliance
The following products have shown compliance through direct testing (of the identified standards below) and design analysis
(through the creation of a technical construction file) to the European Low Voltage Directive (2014/35/EU) when used as
directed by the appropriate documentation.
■
Product compatibility
Type: Programmable controller (open-type device)
*1 Area-specific model
For the products above, programmable controllers manufactured
before March 31st, 2018 are compliant with EN61131-2:2007.
Programmable controllers manufactured after April 1st, 2018 are compliant with EN61131-2: 2007 and IEC 61010-2-201:
2018.
*2
*2 For some models, programmable controllers manufactured in March, 2018 are compliant with LVD directive successively.
Caution for compliance with EC Directive
• Please use the FX5 CPU modules while installed in conductive shielded control panels under a general industrial
environment.
• Please use the programmable controller while installed within a conductive shielded control panel. Please secure the
control box lid to the control box (for conduction). Installation within a control panel greatly affects the safety of the system
and aids in shielding noise from the programmable controller.
• For the control panel, use the product having sufficient strength, fire protectiveness and shielding property to an installation
environment.
• 24VDC of the power supply must be supplied from the circuit double/reinforced insulated from the main power supply
(MAINS).
• For the AC power supply input cable of modules manufactured in or before November 2020 (serial number 20Y****) shown
below, wind a ferrite core around it once near the module.
• When not using the peripheral connector during operation, close the peripheral connector cover. In addition, if there is a
possibility that the built-in Ethernet communication connector may be touched in operation, be sure to eliminate the static
electricity or attach an Ethernet cap
*1
to prevent the influence of static electricity.
*1 Reference product: MJ-JP68K manufactured by JST Mfg. Co., Ltd.
from October 1st, 2014
FX5U-32MR/ES, FX5U-32MT/ES, FX5U-32MT/ESS, FX5U-64MR/ES, FX5U-64MT/ES, FX5U-64MT/ESS, FX5U-80MR/
ES, FX5U-80MT/ES, FX5U-80MT/ESS, FX5-8EYR/ES, FX5-16EYR/ES, FX5-32ER/ES, FX5-32ET/ES, FX5-32ET/ESS,
FX5-1PSU-5V
from May 1st, 2016
FX5U-32MR/DS, FX5-32ER/DS
from October 1st, 2016
FX5U-64MR/DS, FX5U-80MR/DS, FX5-16ER/ES
from January 1st, 2019
FX5UC-32MR/DS-TS, FX5-C16EYR/D-TS
from October 1st, 2019
FX5UJ-24MR/ES FX5UJ-24MT/ES FX5UJ-24MT/ESS, FX5UJ-40MR/ES FX5UJ-40MT/ES FX5UJ-40MT/ESS, FX5UJ-
60MR/ES FX5UJ-60MT/ES FX5UJ-60MT/ESS
from October 1st, 2021
FX5S-30MR/ES, FX5S-30MT/ES, FX5S-30MT/ESS, FX5S-40MR/ES, FX5S-40MT/ES, FX5S-40MT/ESS, FX5S-60MR/
ES, FX5S-60MT/ES, FX5S-60MT/ESS, FX5S-80MR/ES
, FX5S-80MT/ES
, FX5S-80MT/ESS
Compliance with LVD directive
Remarks
EN61131-2:2007 Programmable controllers
• Equipment requirements and tests
The equipment has been assessed as a component for fitting in a suitable
control box which meets the requirements of EN61131-2:2007.
EN IEC 61010-2-201:2018
Safety of electrical equipment for measurement, control, and test
The equipment has been assessed as a component for fitting in a suitable
control box which meets the requirements of EN IEC 61010-2-201:2018.
Item
Description
Ferrite core used in tests by Mitsubishi Electric
E04SR401938 (SEIWA ELECTRIC MFG. CO., LTD.)
Target modules
FX5UJ-40MR/ES FX5UJ-40MT/ES FX5UJ-40MT/ESS
FX5UJ-60MR/ES FX5UJ-60MT/ES FX5UJ-60MT/ESS
Summary of Contents for MELSEC iQ-F FX5UC Series
Page 2: ......
Page 142: ...140 8 CONNECTOR CONVERSION MODULE PERFORMANCE SPECIFICATIONS 8 2 External Dimensions MEMO ...
Page 144: ...142 9 SD MEMORY CARD PERFORMANCE SPECIFICATIONS 9 2 Formatting MEMO ...
Page 146: ...144 10 BATTERY PERFORMANCE SPECIFICATIONS 10 2 Battery Life MEMO ...
Page 277: ...I 275 MEMO ...
Page 281: ......