252
14 PROCEDURES BEFORE OPERATION
14.15 Monitoring the Program
Monitoring on the ladder editor
The ON/OFF states of contacts and coils and the current values of word devices and labels can be monitored on the ladder
editor.
1.
Select [Online]
[Monitor]
[Start Monitoring] on the menu bar.
2.
Monitor the ON/OFF states of contacts and coils and the current values of word devices and labels.
■
ON/OFF state display
The ON/OFF states are displayed on the editor as follows:
■
Changing the current value
To change the current value, select the cell on the ladder editor, and press
+ double-click the cell or press
+
while the program is being monitored.
The program can also be monitored on the Device/Buffer Memory Batch window of the Watch window.
(
GX Works3 Operating Manual)
(1) The ON/OFF states of the contacts and coils
are displayed.
(2) The current value of the word/double word type
data is displayed.
(1)
(2)
(1)
Summary of Contents for MELSEC iQ-F FX5UC Series