![Mitsubishi Electric FR-D710W-0.1K Instruction Manual Download Page 172](http://html.mh-extra.com/html/mitsubishi-electric/fr-d710w-0-1k/fr-d710w-0-1k_instruction-manual_239791172.webp)
170
Selection of operation mode and operation location
(6) PU/External combined operation mode 1
(setting "3")
(7) PU/External combined operation mode 2
(setting "4")
Select the PU/External combined operation mode 1
when applying frequency command from the
operation panel or parameter unit (FR-PU04/FR-
PU07) and inputting the start command with the
external start switch.
Select "3" for
Pr. 79
. You cannot change to the other
operation mode.
When a frequency is applied from the external signal
by multi-speed setting, it has a higher priority than
the frequency command from the PU. When AU is
ON, the command signal to terminal 4 is used.
Select the PU/External combined operation mode 2 when
applying frequency command from the external
potentiometer, multi-speed or JOG signal and inputting the
start command by key operation of the operation panel or
parameter unit (FR-PU04/FR-PU07).
Select "4" for
Pr. 79
. You cannot change to the other
operation mode.
SD
STF
STR
Inverter
Operation
panel
Forward rotation start
Reverse rotation start
3
4
5 6
7
8
9
10
Hz
5
10
2
Frequency
setting
potentiometer
Inverter
Operation
panel