Selection of operation mode and operation location
(1) Operation mode basics
(2) Operation mode switching method
The operation mode specifies the source of the start command and the frequency command for the inverter.
Basically, there are following operation modes.
External operation mode: For inputting start command and frequency command with an external potentiometer and
switches which are connected to the control circuit terminal.
PU operation mode: For inputting start command and frequency command with the operation panel or parameter unit
(FR-PU04 / FR-PU07).
Network operation mode (NET operation mode): For inputting start command and frequency command with RS-485
communication through PU connector.
The operation mode can be selected from the operation panel or with the communication instruction code.
REMARKS
Either "3" or "4" may be set to select the PU/External combined mode.
for details.
The stop function (PU stop selection) activated by pressing
of the operation panel and parameter unit (FR-PU04/FR-
PU07) is valid even in other than the PU operation mode in the initial setting.
(
Refer to Pr. 75 Reset selection/disconnected PU detection/PU stop selection (page
REMARKS
Refer to the following for switching by the external terminal.
PU operation external interlock signal (X12)
PU-External operation switch-over signal (X16)
External-NET operation switchover signal (X65), NET-PU operation switchover signal (X66)
Pr. 340 Communication startup mode selection
External
operation mode
Personal computer
Personal computer
FR-PU07
Programmable controller
Potentiometer
Switch
Inverter
GOT
PU connector
1
2
3
4
5 6
7
8
9
10
PU operation mode
Network
operation mode
PU operation mode
Control terminal
Operation panel
Press on
the PU to light
Switching through the network
Switch to Network operation
mode through the network.
Switch to External
operation mode through
the network.
External operation
Switching with the PU
Network operation
PU operation
Network operation
PU operation
Press on
the PU to light
When "0 or 1" is set in
Pr. 340
When "10" is set in
Pr. 340
Press on the PU to light
Press on the PU to light