46
DRIVE THE MOTOR
C9
(930)
*9,*11
Current output bias
current
0 to 100%
0%
C10
(931)
*9,*11
Current output gain
signal
0 to 100%
100%
C11
(931)
*9,*11
Current output gain
current
0 to 100%
100%
C38
(932)
*9
Terminal 4 bias
command (torque/
magnetic flux)
0 to 400%
0%
C39
(932)
*9
Terminal 4 bias
(torque/magnetic
flux)
0 to 300%
20%
C40
(933)
*9
Terminal 4 gain
command (torque/
magnetic flux)
0 to 400%
150%
C41
(933)
*9
Terminal 4 gain
(torque/magnetic
flux)
0 to 300%
100%
C42
(934)
*9
PID display bias
coefficient
0 to 500.00,
9999
9999
C43
(934)
*9
PID display bias
analog value
0 to 300.0%
20%
C44
(935)
*9
PID display gain
coefficient
0 to 500.00,
9999
9999
C45
(935)
*9
PID display gain
analog value
0 to 300.0%
100%
977
Input voltage mode
selection
0, 1
0
989
Parameter copy
alarm release
10
*2
10
*2
100 *
3
100 *
3
990
PU buzzer control
0, 1
1
991
PU contrast
adjustment
0 to 63
58
992
Operation panel
setting dial push
monitor selection
0 to 3, 5 to 14,
17 to 20, 22 to
35, 38, 40 to 45,
50 to 57, 61, 62,
64, 67, 87 to 97,
100
0
994
Droop break point
gain
0.1 to 100%,
9999
9999
995
Droop break point
torque
0.1 to 100%
100%
Parameter Name
Setting Range
Initial
Value
997
Fault initiation
0 to 255, 9999
9999
998
PM parameter
initialization
0, 3003, 3103,
8009, 8109,
9009, 9109
0
999
Automatic parameter
setting
1, 2, 10 to 13,
20, 21, 9999
9999
1002
Lq tuning target
current adjustment
coefficient
50 to 150%,
9999
9999
1003
Notch filter
frequency
0, 8 to 1250Hz
0
1004
Notch filter depth
0 to 3
0
1005
Notch filter width
0 to 3
0
1006
Clock (year)
2000 to 2099
2000
1007
Clock (month, day)
101 to 131, 201
to 229, 301 to
331, 401 to 430,
501 to 531, 601
to 630, 701 to
731, 801 to 831,
901 to 930,
1001 to 1031,
1101 to 1130,
1201 to 1231
101
1008
Clock (hour, minute)
0 to 59, 100 to
159, 200 to 259,
300 to 359, 400
to 459, 500 to
559, 600 to 659,
700 to 759, 800
to 859, 900 to
959, 1000 to
1059, 1100 to
1159, 1200 to
1259, 1300 to
1359, 1400 to
1459, 1500 to
1559, 1600 to
1659, 1700 to
1759, 1800 to
1859, 1900 to
1959, 2000 to
2059, 2100 to
2159, 2200 to
2259, 2300 to
2359
0
1020
Trace operation
selection
0 to 4
0
1021
Trace mode selection
0 to 2
0
1022
Sampling cycle
0 to 9
2
1023
Number of analog
channels
1 to 8
4
1024
Sampling auto start
0, 1
0
1025
Trigger mode
selection
0 to 4
0
1026
Number of sampling
before trigger
0 to 100%
90%
Parameter Name
Setting Range
Initial
Value
Simple
Simple
Simple
Simple
Simple
Simple
*2
For FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower
*3
For FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher
*9
The parameter number in parentheses is the one for use with the parameter unit (FR-PU07).
*11
The setting is available only with the CA type.
Summary of Contents for FR-A800