SPECIFICATIONS
8.1.3 FR-A842 (400V class)
*1
The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.
*2
The rated output capacity indicated assumes that the output voltage is 440V.
*3
The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow time
for the inverter and motor to return to or below the temperatures under 100% load.
*4
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range. However,
the maximum point of the voltage waveform at the inverter output side is the power supply voltage multiplied by about
√
2.
*5
Value for the ND rating
*6
FR-DU08: IP40 (except for the PU connector section)
*7
For the power voltage exceeding 480V, set Pr. 977 "Input voltage mode selection". (For details, refer to the FR-A800 Instruction Manual.)
For ratings of the converter unit (FR-CC2) refer to the FR-CC2 Instruction Manual.
8.1.4 FR-A846 (400V class)
*1
The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.
*2
The rated output capacity indicated assumes that the output voltage is 440V.
*3
The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow time
for the inverter and motor to return to or below the temperatures under 100% load.
*4
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range. However,
the maximum point of the voltage waveform at the inverter output side is the power supply voltage multiplied by about
√
2.
*5
Value for the ND rating
*6
The rated input current indicates a value at a rated output voltage. The impedance at the power supply side (including those of the input reactor and
cables) affects the rated input current.
*7
The power supply capacity is the value when at the rated output current. It varies by the impedance at the power supply side (including those of the input
reactor and cables).
*8
For the power voltage exceeding 480V, set Pr. 977 "Input voltage mode selection". (For details, refer to the Instruction Manual.)
*9
UL Type 12 Enclosure-Suitable for Installation in a Compartment Handling Conditioned Air (Plenum)
*10
For compliance with IP55, remove the protective bushes and install the recommended cable glands.
Model FR-A842-
07700
(315K)
08660
(355K)
09620
(400K)
10940
(450K)
12120
(500K)
Applicable motor capacity
[kW]
*1
SLD
400
450
500
—
—
LD
355
400
450
500
—
ND (initial setting)
315
355
400
450
500
HD
280
315
355
400
450
Ou
tpu
t
Rated capacity [kVA]
*2
SLD
587
660
733
834
924
LD
521
587
660
733
834
ND (initial setting)
465
521
587
660
733
HD
417
465
521
587
660
Rated current [A]
SLD
770
866
962
1094
1212
LD
683
770
866
962
1094
ND (initial setting)
610
683
770
866
962
HD
547
610
683
770
866
Overload current rating
*3
SLD
110% of rated motor capacity for 60s, 120% of rated motor capacity for 3s (max. surrounding air temperature 40°C)
LD
120% of rated motor capacity for 60s, 150% of rated motor capacity for 3s (max. surrounding air temperature 50°C)
ND (initial setting)
150% of rated motor capacity for 60s, 200% of rated motor capacity for 3s (max. surrounding air temperature 50°C)
HD
200% of rated motor capacity for 60s, 250% of rated motor capacity for 3s (max. surrounding air temperature 50°C)
Rated voltage
*4
Three-phase 380 to 500V
Regenerative braking torque
*5
(when the converter unit
FR-CC2 is used)
Maximum brake
torque
10% torque/continuous
Inpu
t p
o
w
e
r
Control power supply auxiliary input
Single-phase 380 to 500V 50Hz/60Hz
*7
DC power supply voltage
430 to 780VDC
Permissible control power supply auxiliary input
fluctuation
Frequency ±5%, voltage ±10%
Protective structure (IEC 60529)
*6
IP00
Cooling system
Forced air cooling
Weight [kg]
163
163
243
243
243
Model FR-A846-
00023
(0.4K)
00038
(0.75K)
00052
(1.5K)
00083
(2.2K)
00126
(3.7K)
00170
(5.5K)
00250
(7.5K)
00310
(11K)
00380
(15K)
00470
(18.5K)
Applicable motor capacity
[kW]
*1
LD
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
ND (initial setting)
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
Ou
tp
u
t
Rated capacity [kVA]
*2
LD
1.6
2.7
3.7
5.8
8.8
12
18
22
27
33
ND (initial setting)
1.1
1.9
3
4.6
6.9
9.1
13
18
24
29
Rated current [A]
LD
2.1
3.5
4.8
7.6
11.5
16
23
29
35
43
ND (initial setting)
1.5
2.5
4
6
9
12
17
23
31
38
Overload current rating
*3
LD
120% of rated motor capacity for 60s, 150% of rated motor capacity for 3s (max. surrounding air temperature 40°C)
ND (initial setting)
150% of rated motor capacity for 60s, 200% of rated motor capacity for 3s (max. surrounding air temperature 40°C)
Rated voltage
*4
Three-phase 380 to 500V
Regenerative braking
Maximum brake
torque
*5
10% torque/continuous
Po
we
r sup
pl
y
Rated input AC voltage/frequency
Three-phase 380 to 500V 50Hz/60Hz
*8
Permissible AC voltage fluctuation
323 to 550V 50Hz/60Hz
Permissible frequency fluctuation
±5%
Rated input current [A]
*6
LD
2.1
3.5
4.8
7.6
11.5
16
23
29
35
43
ND (initial setting)
1.5
2.5
4
6
9
12
17
23
31
38
Power supply capacity
[kVA]
*7
LD
1.6
2.7
3.7
5.8
9
12
18
22
27
33
ND (initial setting)
1.1
1.9
3
4.6
6.9
9
13
18
24
29
Protective structure
*9
IEC 60529
Dust- and water-proof type (IP55)
*10
UL50
UL Type12
*9
Cooling system
Self-c internal fan
Forced air c internal fan
Weight [kg]
15
15
15
15
16
17
26
26
27
27