17 Troubleshooting
17-180 Occurrence of errors of Tracking and Vision Sensor
Error
number
Error description
Causes and actions
L2560
Illegal parameter of
Tracking
<When the detailed number is 00000>
[Causes]
The value set as the parameter [EXTENC] is outside the range. The
ranges are 1
-8.
[Actions]
Please
confirm the value set to
Parameter
[EXTENC].
<When the detailed number is 01000>
[Causes]
The Q173DPX unit is not installed in the slot specified for the parameter
"ENCUNITn" (n=1
-3).
[Actions]
Please
confirm
whether the Q173DPX unit is installed in the slot
specified for parameter "ENCUNITn" (n=1
-3).
<When the detailed number is 03000>
[Causes]
The base number and slot number specified for the parameter
"ENCUNITn" (n=1
-3) is out of range.
[Actions]
Please confirm whether slot 0
-
2 of a basic base is not specified by
setting the parameter.
<When the detailed number is 04000>
[Causes]
・
The setting value for reading the parameter "TRKENCn" (n=1
-8)
exceeds the range of "ENCRGMN" to "ENCRGMX".
・
The values of the second element and fourth element of the parameter
"TRKENCn" (n=1
-8) are the same when the TrkArc command is
executed.
[Actions]
Check the setting value of the parameter "TRKENCn" (n=1
-8).
L2570
Installation slot error.
[Causes]
Q173DPX is installed in slot 0
-
2 of a basic base.
[Actions]
Slot 0-
2 of the basic base is basically only for CPU. Please install
Q173DPX since slot3.
L258
0
No workpiece in the
tracking area.
[Causes]
There is no workpiece in the tracking buffer or “TrkMv On” command is
executed
Before the workpiece enters to the tracking area.
[Actions]
Execute “TrkMv On” command when the workpiece is in the tracking
area.
L3982
Cannot be used
(singular point)
[Causes]
1) This robot does not correspond to the singular point function
2) Cmp command is executed
3) A synchronous addition axis control is effective
4) Tracking mode is effective
5) Pre
-fetch execution is effective
6) This robot is a setting of the multi mechanism
7) ColChk On command is executed
[Actions]
1) Check the argument of Type specification
2) Invalidate a compliance mode (execute Cmp Off)
3) Invalidate a synchronous addition axis control
4) Invalidate a
tracking mode (execute Trk Off)
5) Invalidate a pre
-fetch execution
6) Do not use the function of passage singular point
7) Invalidate a collision detection (execute ColChk Off)
Summary of Contents for CR800 Series