![Mitsubishi Electric CR800 Series Instruction Manual Download Page 185](http://html.mh-extra.com/html/mitsubishi-electric/cr800-series/cr800-series_instruction-manual_238852185.webp)
16 In such a case (improvement example)
The adsorption position shifts (high speed and accuracy tracking system (vision tracking)) 16-173
16.2.
The adsorption position shifts (high speed and accuracy tracking system (vision
tracking))
When the place that shifts from the specified adsorption position has been adsorbed, the cause is
investigated according to the following procedures.
Start
Check the position
gap
【
confirmation
1
】
Confirm whether neither the
encoder nor the conveyer slip
Check the slip
of encoder
【
confirmation
2
】
Check whether to recognize the
image center correctly.
Check the vision
【
confirmation 3
】
Check whether the calibration is
correct
The position
shifts
The position
doesn
’
t shift
Adjustment
completion
Fix the encoder
Slip
Not slip
Correctly
recognizes
Recognition is
defective
Change the setting of the
vision sensor
Start
Check the
calibration
Correct
Do the work of the
‘
B
1
’
program again
Start
1
Not correct