104
Trouble Shooting – USB Cable
1. Message "Port Open Error"
❍
Power is not turned on yet.
❍
USB driver is not installed yet.
❍
USB cable is not connected.
In this case, there is no MITS USB driver in device manager screen.
2. There is MITS USB driver in device manager screen.
However, no response when “Start Job” icon is clicked.
❍
Press Shift+ESC to cancel the communication at once.
And then try again.
❍
If there are no response without message, go to
CAM Prefs
→
Board Maker
and re-confirm that RS-232C field is set to USB. and
re-start the software.
3. No response when “Start Job” icon is clicked and Shift+ESC key cannot cancel the
communication.
❍
Turn off the prototyping machine and then try Shift+ESC key to cancel.
❍
If this situation frequently happens, change the properties of USB root
hub in device manager of your computer (See another page)
If everything mentioned above cannot solve the problem, or the
communication is unstable, we recommend using RS-232C serial
communication.
If your computer has no RS-232c port, try USB-Serial conversion cable
which is sold in PC shop.
Summary of Contents for Eleven Auto FPZ-31AT
Page 1: ...PCB Prototyping Machine Eleven Auto FPZ 31AT FPZ 73AT Command Manual MITS Electronics...
Page 6: ...5 Basic Information...
Page 11: ...10 Tools...
Page 15: ...14 Comparison of bit length with ring...
Page 16: ...15 Software Install...
Page 25: ...24 Setting Up the Prototyping Machine...
Page 26: ...25 Connect Prototyping Machine to PC and Other Equipment Eleven Auto FPZ 31AT FPZ 73AT...
Page 30: ...29 Activate the Prototyping Machine...
Page 34: ...33 Preparing Fabrication...
Page 43: ...42 Manual Operation...
Page 55: ...54 Procedure for Fabrication...
Page 72: ...71 Step Milling...
Page 76: ...75 Option Fiducial Positioning Camera...
Page 88: ...87 Start MITS Design Pro and Design View Start MITS Design Pro and Design View...
Page 96: ...95 Option Vacuum Table...
Page 97: ...96 Name of Parts of Vacuum Table...
Page 103: ...102 Trouble Shooting...