Solving Problems with Printing Quality
118
Image
defects cycli-
cal (evenly
spaced).
Lateral image defects have
1–2 mm spacing.
Replace the entire drum kit.
Lateral image defects have
35 mm spacing.
Replace the color toner cartridge.
Lateral image defects have
75 mm spacing.
Replace the image transfer roller.
Lateral image defects have
95 mm spacing.
Replace the entire drum kit.
Lateral image defects have
204 mm spacing.
Replace the fusing unit.
Lateral image defects have
other spacing.
Replace the entire drum kit.
Abnormal
areas (white
or black belt
or spots)
appear.
The toner cartridge may be
defective.
Remove the toner cartridge and check for damage.
If necessary, replace it.
The OPC drum cartridge
may be defective or
scratched.
Remove the OPC drum cartridge and check the photosen-
sitive surface (the green surface) for scratches.
If necessary, replace the entire drum kit.
The fuser oil roller is dirty or
worn.
Remove the fuser oil roller and check the roller surface for
dirt or scratches. If necessary, replace the fuser oil roller.
The fuser belt may be dirty.
Clean the fuser belt.
The fusing unit may be
defective.
Replace the fusing unit.
Symptom
Cause
Solution
ABCDE
ABCDE
ABCDE
ABCDE
Summary of Contents for Magicolor 2200
Page 1: ...magicolor 2200 DeskLaser User s Guide 1800622 001A...
Page 9: ...1 Replacing Consumables...
Page 40: ......
Page 41: ...2 Using Media...
Page 56: ......
Page 57: ...3 Printer Driver Configuration...
Page 86: ......
Page 87: ...4 Maintaining the Printer...
Page 97: ...5 Troubleshooting...
Page 136: ......
Page 137: ...6 Installing Other Accessories...
Page 162: ......
Page 163: ...7 CrownView...
Page 175: ...8 Repacking the Printer...
Page 183: ...A Technical Specifications...
Page 200: ......