24
Operation
Figure 13. Run/Decelerate to Minimum Speed Switch
(shown with bidirectional speed adjust
potentiometer connection)
Decelerate to minimum speed
The circuit shown in Figure 13 may be used to decelerate a
motor to a minimum speed. Closing the switch between S2
and S0 decelerates the motor from set speed to a minimum
speed determined by the MIN SPD trimpot setting. If the MIN
SPD trimpot is set full CCW, the motor decelerates to zero
speed when the switch between S2 and S0 is closed. The
applied direction ACCEL trimpot (FWD or REV) setting
determines the rate at which the drive decelerates. Set the
switch to the RUN position to accelerate the motor to set
speed at a rate determined by the applied direction ACCEL
trimpot setting.