Specifications
Maximum
Armature
Armature
Horsepower
Model
Current
Voltage
Range
RG310
3.0 ADC
0 – 90 VDC
1/20 – 1/8
RG300
10.0 ADC †
0 – 90 VDC
1/4 – 1 †
RG400
10.0 ADC †
0 – 180 VDC
1/2 – 2 †
† Maximum armature current and horsepower range apply when drive is attached to
additional heat sink: Minarik part number 223-0235. Use heat sink when armature
current is above 5 ADC. Heat sinks are pre-mounted on RG300 and RG400 series
cased drives.
AC Line Voltage
RG300/RG310
115 VAC, ±10%, 50/60 Hz, single phase
RG400
230 VAC, ±10%, 50/60 Hz, single phase
Form Factor
1.37 at base speed
Field Voltage
115 VAC Input
50 VDC (F1 to L1); 100 VDC (F1 to F2)
230 VAC Input
100 VDC (F1 to L1); 200 VDC (F1 to F2)
Maximum Field Current
1 ADC
Acceleration Time Range
0.5 – 6 seconds
Deceleration Time Range
0.5 – 6 seconds
Analog Input Voltage Range (isolated; RB1 to S2)
–10 VDC to +10 VDC
Input Impedance (RB1 to S2)
32K
Ω
Load Regulation
1% of base speed or better
Vibration
0.5G max. (0 – 50 Hz)
0.1G max. (>50Hz)
Ambient Temperature Range (chassis drive)
10°C – 55°C
Ambient Temperature Range (cased drive)
10°C – 40°C
Safety Certification
UL file # E132235
CSA file # LR41380
CE Certificate of Compliance
1
Summary of Contents for RG300 Series
Page 8: ......
Page 11: ...3 Dimensions Figure 1 RG300UA RG310UA and RG400UA Dimensions...
Page 12: ...4 Dimensions Figure 2 RG310UA S RG300UA S RG400UA S Dimensions...
Page 15: ...7 Regenerative Drives Figure 4 Four Quadrant Operation...
Page 22: ...14 Installation Figure 8 Cased Drive Connections Field Output Connections see page 19...
Page 51: ...43 Figure 23 RG300 and RG400 Series Block Diagram Block Diagram...
Page 52: ...44 Factory Prewired Connections for Cased Drives Figure 24 Prewired Connections to L1 and L2...
Page 53: ...45 Factory Prewired Connections Figure 25 Prewired Speed Adjust Potentiometer Connections...
Page 61: ...Notes 53...
Page 62: ...Notes 54...