Operation
Regenerative brake
Short the INHIBIT terminals to regeneratively brake the
motor. Reopening the INHIBIT terminals causes the motor to
accelerate to set speed.
The INHIBIT terminals bypass both the MIN SPD circuit
and the deceleration circuit. This causes the motor to stop
rapidly when the INHIBIT terminals are shorted. Braking
torque is determined by the opposite-direction torque setting.
Minarik Corporation offers two accessory plug harnesses for
the INHIBIT terminals:
Minarik
®
Part Number
Description
201–0024
Inhibit plug with 18 in. (46 cm) wires
201–0079
Inhibit plug with 36 in. (91 cm) wires
Always twist inhibit wires and separate them from other
power-carrying wires or sources of electrical noise. Use
shielded cable if the inhibit wires are longer than 18 inches
(46 cm). If shielded cable is used, ground only one end of the
shield to earth ground. Do not ground both ends of the
shield.