47
Line filters
Minarik requires the Corcom® line filters listed in Table 3. If
the exact filter is not available, the specifications are:
L = 0.88 milliHenries.
C = 0.30 microFarads (X); 0.011 microFarads (Y).
R = 680Kohms.
Rated current: 1.4 times maximum DC motor current.
Filter type: Balanced 2-section.
Table 3. Corcom® Filters
Nameplate Current of
Corcom® Filter
Motor Wired to the Drive
Part Number
0 to 4 amps
5VR1
4.1 to 13 amps
20VV1
The filters in Table 3 should be wired to the AC line within
0.25 meters of the drive. The ground connection from the
filter must be wired to solid earth ground (resistance less than
500 ohms); not machine ground. This is very important!
If the end-user is using a CE-approved motor, the correct filter
from Table 1 is all that is necessary to meet the EMC
directives listed herein.
CE Compliance