Installation
ASSUMPTIONS: Minarik drives supply motor voltage from
A1 and A2 terminals. It is assumed throughout this manual
that, when A1 is positive with respect to A2, the motor will
rotate clockwise (CW) while looking at the output shaft
protruding from the front of the motor. If this is opposite of
the desired rotation, simply reverse the wiring of A1 and A2
with each other.
Mounting chassis drives
Drive components are sensitive to electrostatic fields. Avoid
contact with the circuit board directly. Hold the drive by the
chassis only.
Protect the drive from dirt, moisture, and accidental contact.
Provide sufficient room for access to the terminal block and
calibration trimpots.
Mount the drive away from other heat sources. Operate
the drive within the specified ambient operating temperature
range.
Prevent loose connections by avoiding excessive vibration
of the drive.
8