![MIMAKI JFX-1631/1615 Plus Operation Manual Download Page 37](http://html1.mh-extra.com/html/mimaki/jfx-1631-1615-plus/jfx-1631-1615-plus_operation-manual_1800231037.webp)
2-7
2
Basic Operation
s
Test drawing
Make test drawing to check whether there is nozzle clogging or other drawing failures (such as wearing or
missing).
Execution of test drawing
1
Press the
key in the local mode.
2
Press
or
key to select “NOZZLE CHK”.
• Select “HARDEN CHK” to confirm that UV ink has not been cured. (
P.4-37)
3
Press the
key.
• Test drawing is started.
4
Test drawing ends
• Returned to the local mode.
• Execute operation of PXX, when evacuation of the Y-bar is required.
5
Check result of drawing
• When the result is normal, finish the operation.
• When the result is abnormal, execute head cleaning. (
P.2-8)
• Printing is disabled when the following messages are displayed. It is enabled when the message has
disappeared.
“WATER NOT READY”
: The temperature of water in the hot water device has not reached the
predetermined value.
Check before starting test
drawing
• Is media set ? (
P.2-5)
• Is origin point set ? (
P.3-2)
• Is head gap value registered ? (
P.3-6)
Normal pattern
Abnormal patterns
Nozzle drop out
Nozzle missing
Deflection
T E S T DRAW
NOZ Z L E CHK
< EN T >
TEST
* * T E S T DRAW * *
ENTER
Many lines are missing.
The lines are missing as if the
teeth are lost.
The distance between the
lines is narrowing or double
lines are formed.