4-28
Replacing water in water heater tank
In order to keep the ink at an appropriate temperature, operate the
water heating system. Supply antifreeze liquid and water to the hot
water tank in the system. Make sure without fail to check once every
month.
Replace it once a year.
Precautions for replacing
Precautions in handling the antifreeze liquid
• Water cannot be added.
• Water and antifreeze liquid compound ratio should be 2(water) to 1(Antifreeze liquid).
• If only water is filled into the water heater tank without antifreeze liquid, the heads could be damaged
due to freezing etc.
• If only antifreeze liquid is filled into the water heater tank without water, the temperature of the liquid may
not be elevated, causing error.
• In order to check the water quantity necessary for water heater device and the stains inside the water
heater tank, make sure to perform checking of the water heater device once every month.
• If water in the hot water tank frequently becomes insufficient, contact the dealer or our branch.
• Dispose the waste water mixed with antifreeze liquid pursuant to the regulations of your district.
• Be sure to wear goggle and gloves for handling the antifreeze liquid.
• Use the recommended antifreeze liquid by Mimaki. (Antifreeze liquid for replacement: SPC-0394
[1000cc X 2 pieces])
• Do not touch the antifreeze liquid directly. If the antifreeze liquid settles on the skin or clothes,
immediately wash it off with soap and water. If you get antifreeze liquid in your eyes, immediately wash
your eyes with a lot of clean water. Then, consult a doctor as soon as possible.
• Store antifreeze liquid in a dark and cold place.
• Store antifreeze liquid in a place that is out of the reach of children.
• When discarding antifreeze liquid which is no longer needed, entrust them to an industrial waste
disposal contractor, clarifying their contents.
• Before using antifreeze liquid, be sure to read the Material Safety Data Sheet (MSDS).
• When purchasing a hot water tank for spare, contact the dealer or our branch.
• Prepare a polyethylene tank for moving waste the water from hot water tank.
• When water in the hot water tank is insufficient, the error message
shown below is displayed. In this case, replace water with the same
manner as shown below.
ERROR 7 0 5
WA T ER L A CK