5-7
Troubles for which error messages are given on the LCD
5
In
Case of T
ro
uble
Error message
Error messages indicates error numbers.
If any error message is given on the LCD, turn off the power to the device and turn it on after a while.
If the same error message appears again on the LCD, contact your local MIMAKI distributor or MIMAKI office to
call for service.
Error message
Cause
Corrective measure
Head connection can not be
confirmed.
• Turn off the power to the device an
turn it on after a while.
• If the same error message appears
again on the LCD, contact your local
distributor to call for service.
Head temperature can not be read.
There is no PRAM.
Data transmission speed is too fast.
Control circuit board is defective.
Data transmission speed is too slow.
Control circuit board is defective.
Battery shutoff is detected.
• Contact your local distributor to call for
service.
Ink discharge is too late.
• Turn off the power to the device an
turn it on after a while.
• If the same error message appears
again on the LCD, contact your local
distributor to call for service.
Failed to write onto IC.
Head setting failure.
Head data transmission error
The set value to HDC HDPL register
has exceeded H'fff and overflowed.
The device has received data other
than command data.
• Securely connect the interface cable
in position.
• Use an interface cable in
conformance with the standard.
A parameter outside the range of
acceptable numeric values is
received.
• Check the host computer output
setting.
E R R O R 1 0 8
H D C O N N E C T
[ 1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8 ]
E R R O R 1 0 8
H D
T H E R M I S
[ 1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8 ]
E R R O R 1 2 2
C H E C K : S D R A M
E R R O R 1 2 8
H D C
F I F O O V E R
E R R O R 1 2 8
H D C
F I F O U N D E R
E R R O R 1 2 9
B A T T E R Y
E X C H A N G E
E R R O R 1 2 a
H D S
S P E E D
E R R O R 1 2 b
H E A D R O M WR
E R R O R 1 2 e
P - H E A D
I N I T
E R R O R 1 2 e
H E A D T I M I N G
E R R O R 1 3 0
H E A D R O M WR
E R R O R 1 6 1
H D P L O V E R F L OW
E R R O R 2 0 1
C O MM A N D
E R R O R 2 0 2
P A R A M E T E R