6-34
Setting the Interval between Each PUMP Tube Washing Operation in the Standby Mode
The PUMP tube is washed regularly to prevent nozzle clogging caused by ink coagulation in the tube.
1
Press the
key in LOCAL to select the
printing mode.
2
Select [ROUTINE SETUP] of the maintenance menu.
(1)
Press the
key.
(2)
Press
to select [MAINTENANCE] and press the
key.
(3)
Press
to select [ROUTINE SETUP].
(4)
Press the
key.
3
Press
to select [PUMP TUBE WASH].
4
Press the
key.
5
Press
to set the interval between each PUMP
tube washing operation.
• Set value: OFF or 1 to 168 hours
6
Press the
key.
7
Press the
key several times to end the setting.
• This function can be performed only when the states shown by the screens below are maintained.
• When the machine has not been filled with cleaning solution, the
screen on the right appears in Step 5. Fill the machine with
cleaning solution (
P.6-10) and perform the operations in Step 1
and later.
• If the cleaning solution is not set, it does not work.* Set the
cleaning solution.
*
For [!Wash Liquid END], it works to use up the cleaning solution, however, replace early.
< LOCA L . 1 >
[ # 0 1 ]
* REMOT E . 1 *
[ # 0 1 ]
0 . 0 0m
LOCAL
REMOTE
< LOCA L . 1 >
[ # 0 1 ]
WI DTH : * * * * mm
ROUT I NE SE TUP
PUMP TUBE WASH < e n t >
ROUT I NE SE TUP
WASH I NT ERVA L
=
1
h
ROUT I NE SE TUP
WASH I NT ERVA L
=
4
h
ROUT I NE SE TUP
PUMP TUBE WASH < e n t >
* Wa s h L i q u i d U N - F I L L *
< LOCA L .
C
> ! WSH
[ # 0 1 ]
CUT 1 ( 3 0 /
6 0 /
0 . 3 0 )
< LOCA L . 1 >
[ # 0 1 ]
! Wa s h L i q u i d C a r t . NONE
or
Summary of Contents for CJV30-100BS
Page 1: ...MIMAKI ENGINEERING CO LTD URL http www mimaki co jp D201979 13...
Page 15: ...xiv How to Read this Manual...
Page 16: ...xv...
Page 128: ...3 52...
Page 254: ...7 14...
Page 269: ...8 15 Function Flowchart 8 Appendix...
Page 283: ...8 29 Function Flowchart 8 Appendix...
Page 291: ...8 37 Function Flowchart 8 Appendix...
Page 294: ...8 40...
Page 295: ...D201979 13 19012011...