![Milltronics Mercap MCP01 D series Instruction Manual Download Page 7](http://html1.mh-extra.com/html/milltronics/mercap-mcp01-d-series/mercap-mcp01-d-series_instruction-manual_1796996007.webp)
7ML19981CM01.1
MERCAP – INSTRUCTION MANUAL
Page 5
Technical Specifications
Electrodes
Process connections
Screw mounting:
Flange mounting:
NPT, BSPT, JIS.
ANSI, DIN
Process material:
C 22.8 N, AISI 316 L, Monel 400, Hastelloy C22
Probe diameter (mm/inch):
9/0.35 (cable), 16/0.63 (rod), or 24/0.95 (rod)
Probe length (mm/inch)
Rod version:
Cable version:
5500/216
35000/1378
Probe lining:
PFA, Enamel, PTFE
Pressure rating (bar/psi):
FV - 200/2920 up to 525/7665 as option
Temperature rating (
°
C/
°
F):
-200
°
/-328
°
to 200
°
/392
°
up to 450
°
/842
°
as option
Wetted Parts
Liner:
PFA/PTFE
Flange:
stainless steel or teflon lined
Transmitter
Measurement range (pF):
0 – 3300
Span (pF):
minimum 3.3
Supply voltage (Vdc):
•
maximum 33
•
minimum 12 Vdc at 3.6 mA
•
minimum 9.5 Vdc at 22 mA
Output current (mA):
3.6 – 22 / 22 - 3.6 (2-wire current loop)
Smart communication:
Acc. the HART Communication Foundation (HCF)
Temperature range (
°
C/
°
F):
-40
°
/-40
°
to 85
°
/185
°
(ATEX–Explosion Proof: -20
°
/-4
°
to
60º/140º)
Siemens Automation