Do not run the left Y Motor Wire through the X Drag Chain. Close the gates.
On the back of the X Extrusion, make sure your drag chain mount on the left of the machine (as viewed from
th
e rear of the machine) is about 1.5” from the left of the extrusion.
The left Y motor wire (on the right as viewed from the rear of the machine)
will be zip tied to the bottom of the X drag chain mount.
Curl the X drag chain around to the left (as viewed from the rear of the
machine) and attach the end of the drag chain to the slot in the left most
drag chain mount with a M4x12 machine screw and a M4 Nylock nut. Move
the X/Z assembly all the way to the left. Zip Tie the drag chain to the slot in
the second drag chain mount before the drag chain curls up.
Locate the long drag chain. Attach the drag chain to the underside of the
drag chain bracket on the right Y motor mount using (2) M4x12 machine
screws and (2) M4 nylock nuts. Open the gates on the back of the drag
chain and stretch out the chain.
The wires that will run through the Y drag chain are:
Z Motor Wire
Left Y Motor Wire
X Motor Wire
Right Y Motor Wire
Router Power Cord Extension
X Homing Switch
Z Homing Switch