Chapter 7 Installation
V
CPU
3,6V
I
out max
68,97µA
R
load max
59k3
C
load max
200nF
General
Low
<2,3V
High
>2,4V
PWM
Measurement
range
1...99%
f
max
25Hz (at 50%
pulse duty factor)
Minimum pulse
length
20ms
Frequency
Measurement
range
1...25Hz (at 50%
pulse duty factor)
Day and pulse
counter
Minimum pulse
length
20ms
7.4.4.4 Temperature modes (PT1000, KTY81110, KTY81210, NI1000, TK5000)
If a universal input is operated in one of the temperature modes, a temperature sensor can be connected
directly to the universal input without an additional energy supply.
Schematic diagram: Universal input in one of the temperature modes
1
myDatalogNANO
2
Compatible temperature sensor
Typ. resolution
0,5°C (depending on the sensor used)
Measurement range
-20...+80°C , accuracy: <=3.0°C (offset adjusted)
-40...+150°C , accuracy: >3.0°C
Load
680k2
Supported sensors
PT1000, KTY81-120, KTY81-210, Ni1000, Ni1000/TK5000