5.1.3 Scale module
This module rescales the raw value (e.g. frequency) to the required measurement value (e.g. mm). The scale
module is only available for the 5 universal inputs.
The following table specifies the relevant parameters for the module:
Configuration section
Mode
Parameter
Explanation
Measurement channels ->
Basis
Digital
Invert
Inverts the input signal
Cnt.Day
Pulse
Metered measurand of a pulse in the
measurement unit
Cnt.Intrvl.
Freq
Factor
Factor by which the input signal is multiplied
PWM
Spannung
PWM
0%
Start of the measurement range in the
measurement unit
100%
End of the measurement range in the
measurement unit
PT1000
KTY81110
KTY81210
NI1000
TK5000
---
---
5.1.4 Decay module
The decay module is designed to summarise several measurement values. The average value over a
required time frame or the minimum value within a required time frame can be determined, for example. The
decay module is only available for the 5 universal inputs, with the exception of "Cnt.Day" channel mode.
The following table specifies the relevant parameters for the module:
Configuration section
Mode
Parameter
Explanation
Measurement channels -
>Config.
Digital
Decay
Temporal function in the measurement cycle
Time
Time x, that is used for decay modes "up",
"down" and "up & down"
Cnt.Day
---
---
Cnt.Intervl.
Freq
PWM
Voltage
PT1000
KTY81110
KTY81210
NI1000
TK5000
Decay
Temporal function in the measurement cycle
Time
Decay period. Up to a maximum of 60
measurement valuescan be used for the
calculation (e.g. 1 channel: 60 measurement
values; ... 4 channels: 15 measurement
values each). To calculate the number of
measurement values that are taken into
account, refer to "Example to clarify the
record interval, measurement cycle and
burst interval in conjunction with the decay"
in chapter "Basic setting" on page 87.
28
Rev. 02
Summary of Contents for myDatalogNANO
Page 2: ......
Page 8: ......
Page 9: ...Chapter 2 Declaration of conformity Chapter 2 Declaration of conformity Rev 02 9 ...
Page 10: ......
Page 12: ......
Page 22: ......
Page 34: ......
Page 38: ......
Page 58: ......
Page 92: ......
Page 108: ......
Page 118: ......
Page 120: ......
Page 126: ......
Page 130: ......