7.3 Safety instructions for the cabling
When connections are made to the myDatalogNANO , the following warnings and information must be
observed, in addition to the warnings and information found in the individual chapters on the installation.
Further safety information is included in "Safety instructions" on page 13.
7.3.1 Information on preventing electrostatic discharges (ESD)
Important note:
Maintenance procedures that do not require the device to be connected to the
power supply should only be performed once the device has been disconnected from the mains
power supply to minimise hazards and ESD risks.
The sensitive electronic components inside the device can be damaged by static electricity, which can impair
the device performance or even cause the device to fail. The manufacturer recommends the following steps
to prevent any damage to the device caused by electrostatic discharges:
l
Discharge any static electricity present on your body before handling the electronic components of the
device (such as circuit boards and components attached thereto). To do this, you can touch a grounded
metallic surface such as the housing frame of a device or a metal pipe.
l
Avoid any unnecessary movements to prevent the build-up of static charges.
l
Use antistatic containers or packaging to transport components that are sensitive to static.
l
Wear an antistatic wristband that is grounded via a cable to discharge your body and keep it free of
static electricity.
l
Only touch components that are sensitive to electric charges in an antistatic working area. If possible,
use antistatic mats and work pads.
7.4 Electrical installation
Important note:
Only qualified personnel should undertake the installation described in this chapter
of the operating instructions to avoid any damage to the device.
7.4.1 Connecting the sensors
Important note:
l
Ensure installation is completed correctly.
l
Comply with existing legal and/or operational directives.
l
Improper handling can cause injuries and/or damage to the instruments!
l
Run all data cables so that they do not pose a trip hazard and ensure that cables do not have
any sharp bends.
l
The myDatalogNANO must not be operated in the field with the lid open.
44
Rev. 02
Summary of Contents for myDatalogNANO
Page 2: ......
Page 8: ......
Page 9: ...Chapter 2 Declaration of conformity Chapter 2 Declaration of conformity Rev 02 9 ...
Page 10: ......
Page 12: ......
Page 22: ......
Page 34: ......
Page 38: ......
Page 58: ......
Page 92: ......
Page 108: ......
Page 118: ......
Page 120: ......
Page 126: ......
Page 130: ......