4. Insert the new feed roller into its
compartment:
a) Mount the roller with a white cap at
the right of the roller into the roller
shaft at the right side of the
compartment.
b) Hold the lever and move the roller
shaft to the right
horizontally.
Then, insert it into a hollow at the left
side of the roller until it sticks into
place.
Roller shaft
c) Rotate the lever on the roller shaft up
to fasten the roller.
5. After done, put the roller cover back into its compartment.
NOTE
:
•
The recommended replacement point for your Feed Roller Assembly is after
scanning approximately 150,000 scans through the feeder.
•
Please contact your local resellers for purchasing new Feed Roller Assembly.
Roller shaft
Lever