3-24
EZ Match User’s Manual
Tube/Cap Information
Tube/Cap Message Editing by Serial Command
Default Tube/Cap Detection messages are shown in the table below.
All Tube/Cap Detection messages can be modified to meet the requirements of the specific
application.
Note:
A read cycle or read operation will format the No Read, CA_, and TA_ messages in
the following order of precedence:
TA_
(all),
CA_
(all),
No Read
(all)
Serial Cmd:
<
K852,
index,message
>
Options:
Any ASCII string up to 15 characters.
Index
Messages
1
CP_
2
CA_
3
CU_
4
TP_
5
TA_
6
MSG6_
7
MSG7_
8
MSG8_
9
MSG9_
10
MSG10_