8-48
EZ Match User’s Manual
Image Output
Image Output
Good Read
If a Good Read condition is met during the read cycle, the image file corresponding with
the first Good Read will be output. The image file will immediately follow the read cycle
output and postambles. For a Good Read condition to occur, all symbols in the read cycle
must qualify.
No Read
If a No Read condition occurs during the read cycle, the image file corresponding with the
first No Read will output. The image file will immediately follow the read cycle output and
postambles. There are conditions in which the read cycle may have a No Read condition
but the image will
not
be output. For example, if the read cycle is looking for two No Read
symbols in the same image capture but one is a Good Read, the image will not be output,
because it is not considered a No Read image.
Note:
A
Cap Absence
or
Tube Absence
will qualify for image output when
No Read
is
selected. In a
Multi-Operation
read cycle with output set to
As Soon As Possible
, only the
results from the last operation are retained. Therefore, if two operations are active, the first
resulting in a No Read condition and the second
not
resulting in a No Read condition, no
image will be stored.
No Read or Good Read
If a No Read condition or a Good Read condition occurs, the first image of either kind will
be output.
Mismatch
If a Good Read occurs during the read cycle but the image is a Mismatch condition, the
first Mismatch image will be output.
Usage:
This feature allows the user to select what read cycle condition triggers the
image file output.
Definition:
Used to output an image file when a specified read cycle condition has
been met, such as No Read or Good Read. When the read cycle is complete,
the normal read cycle output will occur, including any configured postamble
or preamble data. The read cycle will the check if image output is enabled,
and if the specified read cycle condition has been met. If both these conditions
are true, the image file will be output to the user-specified communication port
in the user-specified image file format.
Serial Cmd:
<
K739,image output mode
,communication port,file format,JPEG quality
>
Default:
Disabled
Options:
0 = Disabled
1 = Good Read
2 = No Read
3 = No Read or Good Read
4 = Mismatch
Summary of Contents for EZ Match
Page 1: ...EZ Match Imager User s Manual P N 83 000044 Rev C...
Page 12: ...xii EZ Match User s Manual Statement of RoHS Compliance...
Page 44: ...2 18 EZ Match User s Manual Send Receive Options...
Page 104: ...4 36 EZ Match User s Manual Postamble...
Page 122: ...5 18 EZ Match User s Manual Additional Notes about Calibration...
Page 244: ...8 60 EZ Match User s Manual EZ Trax Output...
Page 258: ...9 14 EZ Match User s Manual Microscan Symbol Quality Output by ESP...
Page 270: ...10 12 EZ Match User s Manual New Master Pin...
Page 370: ...15 14 EZ Match User s Manual Ordered Output Filter...