4-32
EZ Match User’s Manual
USB HID Interface
Configuration Exceptions for USB
Read Cycle Mode
By default, the imager operates in
Continuous Read Mode
.
If the imager is configured
using Data Matrix symbols, the read cycle mode should be the last item changed before
saving the configuration settings and beginning operation.
This is because all read cycle
modes other than
Continuous Read Mode
require a trigger event. In USB, a trigger event
can only be initiated by serial command. To send a trigger command the imager, the host
application must establish a connection with the imager’s
Microscan HID
interface and
send the trigger command in a
Microscan HID Report
.
The following read cycle conditions are required for the USB EZ Match:
Important:
• To use
Level Mode
, you must enable
Undelimited Start Trigger Character
<K229>
and
Undelimited End Trigger Character
<K230>
.
• To use
Edge Mode
, you must enable and use the
Undelimited Start Trigger Character
<K229>
.
• To use
Serial Mode
, you must use the
Delimited Trigger
defined by
<K201>
, or enable
and use the
Undelimited Start Trigger Character
<K229>
.
• To use
Serial and Edge Mode
, you must use the
Delimited Trigger
defined by
<K201>
, or enable and use the
Undelimited Start Trigger Character
<K229>
.
Communications
For the USB version of the EZ Match, no communications serial commands have any
effect on the imager except the following:
• USB HID Report Status
<K149>
• Preamble
<K141>
• Postamble
<K142>
EZ Button
Default on power-on cannot be disabled
<K770,,default>
=
<K770,,1>
. This ensures a
level of safety for recovering from misconfigured Power-On settings
<Z>
. However, it is not
foolproof, as defaulting with the EZ Button only recovers Custom Default settings, which
can be misconfigured themselves. For this reason,
do not save to Custom Default settings
<Zc>
until the imager’s configuration has been tested.
Symbologies
If the imager is going to be configured with Data Matrix symbols, do not disable Data Matrix
<K479>
. Disabling Data Matrix will prevent the imager from reading configuration symbols.
Serial Cmd:
<
K200,read mode
>
Default:
Continuous
Options:
0 = Continuous Mode
1 = Coninuous Read 1 Output Mode
2 = Level Mode
3 = Edge Mode
4 = Serial Mode
5 = Serial and Edge Mode
Summary of Contents for EZ Match
Page 1: ...EZ Match Imager User s Manual P N 83 000044 Rev C...
Page 12: ...xii EZ Match User s Manual Statement of RoHS Compliance...
Page 44: ...2 18 EZ Match User s Manual Send Receive Options...
Page 104: ...4 36 EZ Match User s Manual Postamble...
Page 122: ...5 18 EZ Match User s Manual Additional Notes about Calibration...
Page 244: ...8 60 EZ Match User s Manual EZ Trax Output...
Page 258: ...9 14 EZ Match User s Manual Microscan Symbol Quality Output by ESP...
Page 270: ...10 12 EZ Match User s Manual New Master Pin...
Page 370: ...15 14 EZ Match User s Manual Ordered Output Filter...