EZ Match User’s Manual
11-19
Camera and IP Setup
IP Threshold
Threshold Mode
Threshold Value
Cycle Min
Usage:
Fixed Mode
works best when decode time must be as short as possible
and the reflectance and illumination of the symbol area is uniform and
unchanging.
Cycle Fixed Mode
is useful in applications where decode
time can be slightly longer, and reflectance and illumination of the symbol
area is uniform and unchanging. Otherwise,
Adaptive Mode
is the preferred
mode.
Definition:
This value switches the image processing threshold mode between the
Adaptive
,
Fixed
, and
Cycle Fixed
modes.
An adaptive routine sets the light/dark threshold using data acquired from
the current read. A fixed routine applies the same gray scale threshold
value to each and every symbol. A cycle fixed routine loops through a
pre-defined range of values (
Cycle Min
to
Cycle Max
) by pre-defined
increments (
Cycle Step
).
Serial Cmd:
<
K512,threshold mode
,threshold value,cycle min,cycle max,cycle step,
adaptive contrast percent
>
Default:
Adaptive
Options:
0 = Adaptive
1 = Fixed
2 = Cycle Fixed
Usage:
A higher value will increase the threshold for distinguishing between light
and dark elements.
Definition:
Determines how the imager will distinguish light pixels from dark pixels.
This value is used for
Fixed Mode
only. When
Adaptive Mode
is set,
this value is ignored.
Serial Cmd:
<
K512,
threshold mode,
threshold value
,cycle min,cycle max,cycle step,
adaptive contrast percent
>
Default:
128
Options:
0 to 255
Definition:
Starting value of the cycle mode.
Serial Cmd:
<
K512,
threshold mode,threshold value,
cycle min
,cycle max,cycle step,
adaptive contrast percent
>
Default:
0
Options:
0 to 255
Important:
Cycle Min must be a smaller numerical value than Cycle Max.
Summary of Contents for EZ Match
Page 1: ...EZ Match Imager User s Manual P N 83 000044 Rev C...
Page 12: ...xii EZ Match User s Manual Statement of RoHS Compliance...
Page 44: ...2 18 EZ Match User s Manual Send Receive Options...
Page 104: ...4 36 EZ Match User s Manual Postamble...
Page 122: ...5 18 EZ Match User s Manual Additional Notes about Calibration...
Page 244: ...8 60 EZ Match User s Manual EZ Trax Output...
Page 258: ...9 14 EZ Match User s Manual Microscan Symbol Quality Output by ESP...
Page 270: ...10 12 EZ Match User s Manual New Master Pin...
Page 370: ...15 14 EZ Match User s Manual Ordered Output Filter...