18
aponorm
®
by
Installation and Data Transmission
1. Insert CD into CD ROM drive of your PC. The installation will
start automatically. If not, please click on «SETUP.EXE»
2. Connect the monitor via cable with the PC – no need to switch
the device on. Three horizontal bars will appear on the display
and last for 3 seconds.
3. The bars will then fl ash to indicate that the connection between
computer and device is successfully made. As long as the cable
is plugged, the bars will keep fl ashing and buttons are disabled.
During the connection, the device is completly controlled by the
computer. Please refer to the «help» fi le for software instructions.
11. PC-Link Functions
This device can be used in connection with a personal computer
(PC) running the Microlife Blood Pressure Analyser (BPA) software.
The memory data can be transferred to the PC by connecting the
monitor via cable with the PC.
12.
10. Using a Mains Adapter
You can operate this instrument using the Microlife mains adapter
(DC 6V, 600mA).
When the mains adapter is connected, no battery current is
consumed.
)
The batteries can NOT be charged in the blood pressure
monitor! Recharge these batteries in an external charger
and observe the information regarding charging, care and
durability!
)
Use only the Microlife mains adapter available as an orig-
inal accessory appropriate for your supply voltage, e.g. the
«Microlife 230V adapter».
)
Ensure that neither mains adapter nor cable are not
damaged.
1. Plug the adapter cable into the mains adapter socket
5
in the
blood pressure monitor.
2. Plug the adapter plug into the wall socket.
You can operate this instrument using the aponorm
®
by microlife
adapter (DC 6V, 600mA).
Use only the aponorm
®
by microlife mains adapter availa-
ble as an original accessory appropriate for your supply
voltage, e.g. the «aponorm
®
by microlife 230V adapter».
11.
Using rechargeable batteries
You can also operate this instrument using rechargeable batteries.
)
Remove batteries, if the instrument is not going to be used
for a prolonged period.
)
Please use only type «NiMH» reusable batteries!
)
The batteries must be removed and recharged, if the battery
symbol (battery flat) appears! They must not remain inside
the instrument, as they may become damaged (total
discharge as a result of low use of the instrument, even
when switched off).
)
Always remove the rechargeable batteries, if you do not
intend to use the instrument for a week or more!
9. Battery Indicator and Battery change
Batteries almost flat
When the batteries are approximately ¾ used the battery symbol
AO
will flash as soon as the instrument is switched on (partly filled
battery displayed). Although the instrument will continue to
measure reliably, you should obtain replacement batteries.
Batteries flat – replacement
When the batteries are flat, the battery symbol
AO
will flash as
soon as the instrument is switched on (flat battery displayed). You
cannot take any further measurements and must replace the
batteries.
Which batteries and which procedure?
1. Open the battery compartment
7
at the back of the instrument
by pushing inwards at the two arrows and pulling out the
battery compartment cover.
2. Replace the batteries – ensure correct polarity as shown by the
symbols in the compartment.
3. To set date and time, follow the procedure described in
«Section 2.».
)
The memory retains all values although date and time (and
possibly also set alarm times) must be reset – the year
number therefore flashes automatically after the batteries
are replaced.
)
Please use 4 new, long-life 1.5V, size AA batteries.
)
Do not use batteries beyond their date of expiry.
10.
11402 Profes_Gebrsanw_innen RZ B.indd 18
03.08.2010 16:45:28 Uhr