31
The
“Special” Calibration Mode
is used to set up system
parameters that rarely need to be changed or adjusted. To
enter Special Cal, put the system in MASTER HOLD, turn
the console OFF, press and hold both the CONT SEL button
and CAL button while turning console ON. The console will
display SPEC for 2 seconds to show that the console is in the
Special Calibration mode.
Calibration Values-Channel 1,2
The following table describes the special cal parameters and
shows the factory settings. More detailed descriptions follow
the table.
NOTE: Each channel has its own independent special-cal
parameters.
“Special” Calibration
Release the CONT SEL and CAL buttons. The CAL icon and
Warn LED will turn on. The desired Special Calibration
parameter(s) can then be accessed with the rotary switch per
the illustration below. To exit Special Calibration, press and
hold the CAL button for 2 seconds. The console will store any
changes and revert to normal operation.
NOTE: you must
exit Special Calibration to save changes.
Special Cal
Fill Tank Size
Units... and...
Valve Voltage
Material
Valve Response Speed
Tank Set Point
Auto Shutoff
On/Off
Auto Delay Time
WIDTH
CAL
FLOW
CAL
MIN
FLOW
ADJUST
RATE
TARGET
RATE
SPEED
CAL
INLINE
BYPASS
TEST
SPEED
VOLUME /
MINUTE
DISTANCE
AREA /
HOUR
VOLUME
(1) (2) (3)
RATE
SPEED
AREA
(1) (2) (3)
CAL
CONT
SEL
RESET
TANK
___
HOLD
Ch2: Operating Mode
*
Special Cal
Parameter
Description
Factory Setting
Ch1: Units
(same for both Ch1, Ch2)
System of units: EnG (English) / mEt (Metric) /TurF (Turf)
EnG (English)
Ch2: Operating Mode
Ch2: Operating Mode: norm (Normal), InJ (Injection), PAr (Parallel)
Ch2: norm (Normal)
Valve Voltage
Servo Valve Drive Voltage (8/12)
12
Material
Choose Liquid (H2O or Anhydrous (NH3)
H2O
Valve Response Speed
Set Valve Response (-4 to 3)
-1
Auto Delay Time
Delay servo response when going from Hold to Run (Off) to 4 sec.)
- Allows slow shutoff valves TIME to open before servo starts moving
1
Auto Shutoff
Runs servo toward minimum when in hold (On/Off)
Off
Tank (Low) Set Point
Sets alarm point if using Tank Function (Off or 1-65,535)
Off
Fill Tank Size
Size (volume) of Full Tank (Off or 1-65,535)
Off