Page 33
Profibus Interface
optoNCDT ILR 1183
7.7
Diagnostic Data
Class 2 functionality Commissioning diagnostic Diagnostic information
-
0
6 byte standard diagnosis
0
1
16 byte class 1 diagnosis
1
1
61 byte class 2 diagnosis
Octet
Bit
Type
Output
1
byte
diag state 1
(profibus default)
2
byte
diag state 2
(profibus default)
3
byte
diag state 3
(profibus default)
4
byte
master address
(profibus default)
5 ... 6
word
ident number
(profibus default)
class 1 diagnostic
7
byte
group ident
(profibus default)
8
byte
spc3 spec
(profibus default)
9
0
bool
unused
1
bool
class 2 functionality on/off
2
bool
commissioning diagnostic on/off
3
bool
unused
4
bool
reserved for future use
5
bool
reserved for future use
6
bool
reserved for manufacturer
7
bool
reserved for manufacturer (operation status: parameter byte 9)
10
byte
encoder type (=7 absolute linear encoder)
11 ... 14
unsigned 32
single turn resolution => 100000 nm = 0.1 mm
15 ... 16
unsigned 16
no. of distinguishable revolutions – unused (=0)
class 2 diagnostic
17
0
bool
E98 – Timeout SIO
1
bool
E99 – unknown error
Summary of Contents for optoNCDT ILR 1183
Page 6: ...optoNCDT ILR 1183...
Page 47: ......